CU Layout (Read 5785 times)
Al_Yeti
Guest









CU Layout
Apr 12th, 2004, 11:10pm
 
Ok ello ello this is cool , anyway enough of that HIT ME!


CU Layout

I have to have to CU's cant do split or single none that ting ok!

I got to MK SENTRY CU one with RCD one with Isolater

FIRST SET UP WITH RCD
1. Down Stairs Ring(32A)
2. Kitchen has three seperate radial legs what to do       with them? dont want to destroy kitchen which is only way to put them on ring.(2*16A)???
3. Shower Electric 10.5kw(50A)


SECOND WITH ISOLATER
4. Up stairs Lighting (6A)
5. Down stairs Lighting  (6A)
6. Boiler(6A)
7. Alarm / Security Lights(6A)
8. Up stairs Ring(32A)


Problem i got is the kitchen sockets what RCD Rating should i use? ad's to 114A's i think anyhow tell me what you think
Back to top
 
 
IP Logged
 
Pro-Spark
GDPR opt-out









Re: CU Layout
Reply #1 - Apr 12th, 2004, 11:20pm
 
Did I read that right that you have 3 radials on 2 mcb's

Tony
Back to top
 
 
IP Logged
 
al-yeti
Guest









Re: CU Layout
Reply #2 - Apr 12th, 2004, 11:58pm
 
not really the radials are on the kitchen at present and everything else will be new as i wont be touching the the kitchen for a while, so there are 6 sockets in total all running from one fuse somewhere via junction box's trouble is i cant put them into a ring so not sure what to do with them???????worse case i will have to chase out the kitchen walls which are a flat roof with no ceiling access.

What about the rest? espcially RCD rating to what i gave
Back to top
 
 
IP Logged
 
plugwash
Administrator
*****
Offline

I love YaBB 1G - SP1!

Posts: 1383


Total Thanks: 0
For This Post: 0



Trade: Not Specified

Re: CU Layout
Reply #3 - Apr 13th, 2004, 10:44pm
 
sockets in any form of radial no matter how it spurs can be put on a 20A breaker if the cable is 2.5mm

normally you would use something like a 80A current rating 30ma trip rcd

generally i would say that all downstairs sockets should be on the rcd expect possibly one specifically for the freezer

whether you put the upstiars sockets on a rcd is your choice
Back to top
 
Thank User For This Post WWW plugwash plugwash 107767391 peter_m_green_zyworld_com plugwash  
IP Logged
 
scotspark
Trade Member
*****
Offline

mmmmm it's gonna cost
you!!
Posts: 3074


Total Thanks: 10
For This Post: 0


scotland, Scotland
scotland
Scotland

Gender: male

Trade: Electrician



Re: CU Layout
Reply #4 - Apr 15th, 2004, 1:37am
 
as plug said bout kitchen on 20A mcb but i'd put all sockets on rcd personally Kiss
Back to top
 

brown to red and blue to f****&&&&ommited!!!!!!!!!!!!!!!!!!!!!!!!!!!
Thank User For This Post View members image gallery  
IP Logged
 
LSpark
Global Moderator
Trade Member
Author
*****
Offline


Posts: 8069


Total Thanks: 3
For This Post: 0


London, UK, United Kingdom
London, UK
United Kingdom

Gender: male

Trade: Electrician



Re: CU Layout
Reply #5 - Apr 15th, 2004, 11:42pm
 
Not sure how you can run 2.5 radial at 20A, if its installed in thermaly insulated wall in or out of conduit, max is 18.5A  Shocked.