Dodgy Freezer (Read 15766 times)
squiggle
GDPR opt-out









Dodgy Freezer
May 22nd, 2004, 11:13am
 
We have an old freezer (bought second hand) that is tripping the main power switch (RCD I think).

I don't intend doing anything other than considering the appliance dangerous and writing it off but can any one explain to me in laymans terms what sort of thing goes wrong to cause this? I can't see a broken or badly connected wire or anything like that.

Jon
Back to top
 
 
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8814


Total Thanks: 108
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: Dodgy Freezer
Reply #1 - May 22nd, 2004, 11:47am
 
The motor (compressor) is a prime suspect.

The slightest bit of damp in it can cause an RCD to trip.

Back to top
 

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
HM
Super Member
*****
Offline

Chief Turd Polisher
Posts: 5072


Total Thanks: 0
For This Post: 0


Gender: male

Re: Dodgy Freezer
Reply #2 - May 22nd, 2004, 12:39pm
 
[quote author=Lectrician  link=1085220826/0#1 date=1085222839]The motor (compressor) is a prime suspect.

The slightest bit of damp in it can cause an RCD to trip. [/quote]
If that is the case then pointing a fan heater at it for an hour or two might relieve the dampness within. Then if the problem goes away and comes back later you'll know you are onto the right cause.

Mind you, probably wouldn't help the freezer contents whilst this was going on!

Andrew
Back to top
 

If you aren't always sure of the right answer don't take up a career in the bomb squad
Thank User For This Post  
IP Logged
 
squiggle
Re: Dodgy Freezer
Reply #3 - May 22nd, 2004, 12:51pm
 
LOL HM.

It went on Thu and we have already lost stuff. Bad time too as we had a musical contact of mine stopping with us (packed her of to Yorkshire for her next leg yesterday). Priority was really to find what was killing the power in the house and at least restore that - to me that was a case of unplug everything and then see what device did the damage, and to get power back.

It's only a small freezer and there is another combi fridge/freezer in the kitchen (the one that went is in the porch area) and we were able to cram at least some more stuff in that.  Priority there in our case was mostly veg - produce from the garden - not as good as fresh from the garden maybe, but still more important than say a pack of frozen peas to us.

Jon
Back to top
 
Thank User For This Post  
IP Logged
 
HM
Super Member
*****
Offline

Chief Turd Polisher
Posts: 5072


Total Thanks: 0
For This Post: 0


Gender: male

Re: Dodgy Freezer
Reply #4 - May 22nd, 2004, 3:11pm
 
[quote author=squiggle  link=1085220826/0#3 date=1085226704]LOL HM [/quote]
I was actually being serious. A small fan heater directed at something which is damp (in this case perhaps the freezer motor) can work wonders with drying out.

The fan heater can also be useful during defrosting of a fridge or freezer - open the door and point the warm air towards it. Helps to defrost that little bit quicker.

However if doing the defrosting it's a good idea not to have the fan heater too close or too high. You just need some gentle warmth breezing in.

Andrew
Back to top
 

If you aren't always sure of the right answer don't take up a career in the bomb squad
Thank User For This Post  
IP Logged
 
squiggle
Re: Dodgy Freezer
Reply #5 - May 22nd, 2004, 4:53pm
 
Sorry, my fault, HM. I should have quoted

"Mind you, probably wouldn't help the freezer contents whilst this was going on! ".

What I was responding to was that in that sense, the damage is already done, not the idea that perhaps a fan heater could cure a problem.

Jon
Back to top
 
Thank User For This Post  
IP Logged
 
HM
Super Member
*****
Offline

Chief Turd Polisher
Posts: 5072


Total Thanks: 0
For This Post: 0


Gender: male

Re: Dodgy Freezer
Reply #6 - May 22nd, 2004, 7:02pm
 
[quote author=squiggle  link=1085220826/0#5 date=1085241239]Sorry, my fault, HM. I should have quoted [/quote]
No problem. I only get worried when there's a rabbit on the other end of the conversation..... Wink

Andrew
Back to top
 

If you aren't always sure of the right answer don't take up a career in the bomb squad
Thank User For This Post  
IP Logged
 
rabbit_rabbit
Re: Dodgy Freezer
Reply #7 - May 22nd, 2004, 10:24pm
 
Now there's a  coincidence!

About 2 months ago I was called out on a Sunday to investigate why main RCD was tripping. No probs say me, the eejit, £45 call out fee.

Anyway, arrive at this enormous house. OK (1) turn off all MCB's until RCD can be reset. (2) Having found which circuit is source of problem isolate everything on that cct.
(3) Three days later and having run some 20 miles up and down stairs (I jest) turns out to be a - FREEZER -insulation breaking down. In the bin, new freezer all OK ever since.

Invoice value = £45.00
Costs = £15,567.00
Profit/(Loss) = (£15,522)

The only good news tax = £0.00

RR



Back to top
 
Thank User For This Post  
IP Logged
 
HM
Super Member
*****
Offline

Chief Turd Polisher
Posts: 5072


Total Thanks: 0
For This Post: 0


Gender: male

Re: Dodgy Freezer
Reply #8 - May 22nd, 2004, 10:45pm
 
Are you saying you charged a callout fee and nothing else?

Sounds like the customer got a good deal! Where I'm concerned it's £25 callout, then £15 an hour after that.

Andrew
Back to top
 

If you aren't always sure of the right answer don't take up a career in the bomb squad
Thank User For This Post  
IP Logged
 
rabbit_rabbit
Re: Dodgy Freezer
Reply #9 - May 22nd, 2004, 11:15pm
 
No, no Andrew it was not really a big mansion and it did not really take me 3 days and I did not really run 20 miles and I did not really make a loss of £15,522

It did take me about 45 minutes to find it was the freezer and I did charge £45 call out.


RR

PS. Sighs...mornin' Andrew
Back to top
 
Thank User For This Post  
IP Logged
 
HM
Super Member
*****
Offline

Chief Turd Polisher
Posts: 5072


Total Thanks: 0
For This Post: 0


Gender: male

Re: Dodgy Freezer
Reply #10 - May 23rd, 2004, 7:14am
 
So how come grasper Brown gets no tax on this job then mate, or shouldn't I be asking leading questions like that?

I'd have thought that 40% of £25 meant that grasper got £10.

Andrew
Back to top
 

If you aren't always sure of the right answer don't take up a career in the bomb squad
Thank User For This Post  
IP Logged
 
rabbit_rabbit
Re: Dodgy Freezer
Reply #11 - May 23rd, 2004, 9:36am
 
Brown, tax, grasper, 40% ?? All strange words to me mate.

RR
Back to top
 
Thank User For This Post  
IP Logged
 
HM
Super Member
*****
Offline

Chief Turd Polisher
Posts: 5072


Total Thanks: 0
For This Post: 0


Gender: male

Re: Dodgy Freezer
Reply #12 - May 23rd, 2004, 9:39am
 
Sorry, forgot you weren't a plumber so I guess I'll have to let you off the 40% Smiley

Andrew
Back to top
 

If you aren't always sure of the right answer don't take up a career in the bomb squad
Thank User For This Post  
IP Logged
 
big_all
Global Moderator
Trade Member
Author
*****
Offline

heeelllooo
Posts: 5596


Total Thanks: 10
For This Post: 0


Gender: male

Trade: Joiner



Re: Dodgy Freezer
Reply #13 - May 23rd, 2004, 9:41am
 
just a thought

youve normaly got a little tank on a fridge
to evapourate the water that comes from
the inside the fridge[attached to the motor]

now it may not have one of these but if it
has could it be leaking causing dampness
on the electrics ??? ??? ???
Back to top
« Last Edit: May 23rd, 2004, 9:42am by big_all »  

big all ---------------  we are all still learning
Thank User For This Post View members image gallery  
IP Logged
 
rabbit_rabbit
Re: Dodgy Freezer
Reply #14 - May 23rd, 2004, 1:33pm
 
Without a doubt that could be a major cause Big_All. You dont think for one second that anyone who actually understands electrics checks the design of freezers, fridges, washing machines, tumbler dryers etc. for safety do ya?

RR
Back to top
 
Thank User For This Post  
IP Logged
 
squiggle
Re: Dodgy Freezer
Reply #15 - May 23rd, 2004, 2:05pm
 
[quote author=rabbit_rabbit  link=1085220826/0#14 date=1085315596]Without a doubt that could be a major cause Big_All. You dont think for one second that anyone who actually understands electrics checks the design of freezers, fridges, washing machines, tumbler dryers etc. for safety do ya?

RR
[/quote]

Well RR, sometimes I did cover for the Design Change Controller (sort of admin for production contol who co-ordinated getting new designs in - lots of considerations and departments - our side material but also QA, maybe production engineering to sort out a new job on the lines, etc) and I can assure you that a DCN (design change notification) marked as a safety change, also had a priority of urgent....

Jon
Back to top
 
Thank User For This Post  
IP Logged
 
squiggle
Re: Dodgy Freezer
Reply #16 - May 23rd, 2004, 2:20pm
 
PS, they do make mistakes and I once picked one up while loading the bill of materials up that no one in design had spotted.

I can't remember exactly but the washing machines used 3 wiring harness - something along the lines of red, green and white - pump, heater and motor. Whatever, their planned design the way it came to me on paper (not a drawing just a list) did something along the lines of using 2 heater harnesses and no pump harness.

I suppose that was one advantage I had there. I worked as a material handler (labourer) on the section where the consoles were assembled (amongst other things) before getting promoted and having a position in the offices. I'd not understand the wiring but I had seen loads of units assembled...

Jon
Back to top
 
Thank User For This Post  
IP Logged
 
Dr_Who
Newbie
*
Offline

I love YaBB 1G - SP1!

Posts: 1


Total Thanks: 0
For This Post: 0



Re: Dodgy Freezer
Reply #17 - May 25th, 2004, 12:13pm
 

Big_all may have hit the nail on the head with this one, but the fault could still be elsewhere on the system! You would need to test the system following the disconnection of some of the major electrical functions of the system in turn. (i.e. compressor, light, thermostat, electronic controls). Can you remember any external influence may may have attributed to this fault - eg any spillages inside or outside the fridge (even on the plug), has the fridge been moved recently.......?

Remember though that the 'motor' is integrated inside the compressor (sealed) and is very very very unlikely to be damp! Check the connections that enter the compressor for 'dampness'!!

Back to top
 
Thank User For This Post  
IP Logged
 
squiggle
Re: Dodgy Freezer
Reply #18 - May 27th, 2004, 8:16pm
 
Again, thanks for the advice. The old freezer was crammed anyway so rather consider possible causes for damp we got a new and larger model.

Looking through the instruction book, I find one bit that intrigues me:

"Never use continuous operation unless unnecessarily required"

It sort of reads to me as "Only use continuous operation when you don't need to"

Jon