elec shower (Read 5298 times)
spot
Junior Member
**
Offline

I love YaBB 1G - SP1!

Posts: 8


Total Thanks: 0
For This Post: 0



elec shower
Sep 9th, 2004, 6:57pm
 
???
heres one for you lot,
i have a 9.5kw shower and at the moment it has a 2.5m
cable going to the pull switch! then from there a 10m cable going to the c.u.
I know i will have to replace the 2.5m cable for 10m.
But here is the question.... the c.u has no RCD fitted so the shower is not protected. can i fit an in line RCD to the shower circuit??? rather than change the whole C.U ?
Back to top
« Last Edit: Sep 12th, 2004, 5:37pm by LSpark »  
Thank User For This Post  
IP Logged
 
Beanzy
Re: elec shower
Reply #1 - Sep 9th, 2004, 8:23pm
 
Yep. Can buy them complete with MCB from TLC, or Screwfix, but may get better price from your wholesalers. Don't forget to sort out the earth bonding too. If unsure re this post a follow-up one on here and will update you.
Back to top
 
Thank User For This Post  
IP Logged
 
The_Trician
Trade Member
*****
Offline


Posts: 7721


Total Thanks: 8
For This Post: 0


Gender: male

Trade: Electrician



Re: elec shower
Reply #2 - Sep 9th, 2004, 10:38pm
 
Don't know what make or age your CU is; but you might be able to get something which will fit straight into it.

More info needed though.

TT
Back to top
 

Thats the trouble with a colostomy - you can never find the shoes to match the bag.......
Thank User For This Post  
IP Logged
 
LSpark
Global Moderator
Trade Member
Author
*****
Offline


Posts: 8069


Total Thanks: 3
For This Post: 0


London, UK, United Kingdom
London, UK
United Kingdom

Gender: male

Trade: Electrician



Re: elec shower
Reply #3 - Sep 10th, 2004, 12:04am
 
Yep, cable will need to be changed, if it's a modern board you can get a RCBO, which is a combined RCD and a MCB (fuse), if it's an older board, the alternative is to fit a seperate box with a RCD in next to the board, and run the shower through this, the RCBO or RCD would been to be 45A.

Back to top
« Last Edit: Sep 10th, 2004, 12:05am by LSpark »  
Thank User For This Post View members image gallery  
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8814


Total Thanks: 109
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: elec shower
Reply #4 - Sep 10th, 2004, 1:16pm
 
Of course, there is actually no requirement to provide an RCD for a shower circuit, as long as the disconnection time of 0.4 seconds can be achieved with a fuse or MCB, which in a domestic environment with 10mm shower cable should be fine.   I would be extremely surprised if the Zs would be exceeded.

But then, for a few quid for an RCD, it would make you feel a little safer - mine has an RCD  Wink

Yep, upgrade your supp bonding as well.
Back to top
 

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
ChubbyPhaseWire
Re: elec shower
Reply #5 - Sep 10th, 2004, 2:14pm
 



Protection against electric shock
Bathrooms and shower rooms
Disconnection times for circuits supplying current-using equipment are no longer reduced to 0.4 s. However, 30 mA RCDs are to be fitted to the circuits of certain items of current-using equipment (see Table 1B)GN7.
Back to top
 
Thank User For This Post  
IP Logged
 
spot
Junior Member
**
Offline

I love YaBB 1G - SP1!

Posts: 8


Total Thanks: 0
For This Post: 0



Re: elec shower
Reply #6 - Sep 10th, 2004, 6:53pm
 
Cheers for the info guys........
yes the C.U is an old type and cant hold an rcbo which would have been a top job! if i put in a new shower C.U would i have to run tails to the mains terminal block or could i get the supply from the original CU? ???

can you run-through the earth  bonding for the shower!
many thanks
spot......................................... Wink
Back to top
« Last Edit: Sep 10th, 2004, 7:00pm by spot »  
Thank User For This Post  
IP Logged
 
plugwash
Administrator
*****
Offline

I love YaBB 1G - SP1!

Posts: 1383


Total Thanks: 0
For This Post: 0



Trade: Not Specified

Re: elec shower
Reply #7 - Sep 10th, 2004, 7:47pm
 
what kind of CU is it there presently

remember the wylex standard CUs with isolators below 100A are not meant to take any protective device over 30A

and good f**king luck getting proetctive devices for any other brand of that age
Back to top
 
Thank User For This Post WWW plugwash plugwash 107767391 peter_m_green_zyworld_com plugwash  
IP Logged
 
Beanzy
Re: elec shower
Reply #8 - Sep 11th, 2004, 12:40am
 
Yes you'd have to sort the meter tails out. Which means you'll have to remove the main fuse and take full precautions. I'd hold fire on any of this one unless you have the necessary test kit. It's safer and probably much quicker to get a pro on this one, not really the realms of DIY. If it were a modern CU which just required the relevant MCB and you had access to test kit, or someone who knew how to drive it, then you could possibly do it. There's too much scope for error with this one as it is.

On the earth bonding issue this can help explain much;

http://www.niceic.org.uk/downloads/NL139supp.pdf

Also get hold of the IEE on site guide if you do or intend to do any DIY electrical work, it's a good base to get proper info before deciding which jobs you may want to do yourself, and which may be a can of worms for you.
Back to top
« Last Edit: Sep 11th, 2004, 12:41am by Beanzy »  
Thank User For This Post  
IP Logged
 
LSpark
Global Moderator
Trade Member
Author
*****
Offline


Posts: 8069


Total Thanks: 3
For This Post: 0


London, UK, United Kingdom
London, UK
United Kingdom

Gender: male

Trade: Electrician



Re: elec shower
Reply #9 - Sep 11th, 2004, 1:39am
 
[quote author=plugwash  link=1094752656/0#7 date=1094842075]what kind of CU is it there presently

remember the wylex standard CUs with isolators below 100A are not meant to take any protective device over 30A

and good f**king luck getting proetctive devices for any other brand of that age [/quote]

lol, calm down  Roll Eyes