I thought that I may have problems with this pump install.

It is in a flat, the CW tank is directly above the HW cylinder, level of water in tank 7FT top of cylinder 4FT approx. Supplies from tank 28mm & 28mm until reduced to each outlet. Elbow out of top of cyl, 300mm of horizontal pipe then Tee, up to vent down to pump.

Fitted a whole house pump which is sucking in air through the vent. There is very little room between the top of the cyl and tank base so would an essex flange be the way to go?

Not fitted one of these before, anything to look out for, the cyl is approx 25yrs old.

Thanks, Jason
Back to top
« Last Edit: Nov 2nd, 2004, 7:37pm by jasonB »  
 
IP Logged
 
billythekid
Trade Member
*****
Offline

I love YaBB 1G - SP1!

Posts: 3402


Total Thanks: 0
For This Post: 0



Trade: Plumber

Re: What flange to use
Reply #1 - Nov 2nd, 2004, 10:23pm
 
sounds like a good idea to me if ya cant raise the cistern. you need to get the right type, flat (E1) is the one you want in 1". Just be careful when cutting the hole for it, but you shouldnt have any trouble, dont drop it inside the cylinder! they give you a wire holder tool to keep that from happening. The rubber washers in an essex flange are suitable for water temp up to 60deg C for temperatures higher than this up to 90deg C get the EPDM washers and for up to 120deg C SX washers.

Hope thats the info ya want

Btk
Back to top
 
Thank User For This Post  
IP Logged
 
jasonB
Re: What flange to use
Reply #2 - Nov 3rd, 2004, 5:20pm
 
Thanks BTK, picked one up thismorning, see what you mean about not dropping bits in the cylinder.

Just one point, should the pipe carry on through the flange into the cylinder and have the end cut at an angle?

Thanks Jason
Back to top
 
Thank User For This Post  
IP Logged
 
jasonB
Re: What flange to use
Reply #3 - Nov 3rd, 2004, 6:31pm
 
Here's the bathroom that the pump will serve if anyone is interested. Just waiting for the client to do the dec's.

http://photobucket.com/albums/v156/jasonballamy/pittplace/?action=view&current=P...

Jason
Back to top
 
Thank User For This Post  
IP Logged
 
supersparky
Administrator
Trade Member
Author
*****
Offline


Posts: 6097


Total Thanks: 3
For This Post: 0


Gender: male

Trade: Electrician



Re: What flange to use
Reply #4 - Nov 3rd, 2004, 6:32pm
 
...

are you god?
we are not worthy!

ss

ps, looks nice
Back to top
« Last Edit: Nov 3rd, 2004, 6:35pm by supersparky »  
Thank User For This Post WWW  
IP Logged
 
jasonB
Re: What flange to use
Reply #5 - Nov 3rd, 2004, 6:34pm
 
Does look like I've got a halo around my head !

J
Back to top
 
Thank User For This Post  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: What flange to use
Reply #6 - Nov 3rd, 2004, 8:37pm
 
At 25 years old I would recommended a new cylinder, cant be worth playing with the old one when it's likely to go at any time. at the very least you should make the client aware of the fact.

An essex flange is the only real choice in my opinion, other than a dedecated tapping.

scruff
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
JerryD
Re: What flange to use
Reply #7 - Nov 3rd, 2004, 8:57pm
 
Jeez, what toothpaste do you use  Cheesy

Back to topic...... if you get a new cylinder, order one with the tappings you want already factory fitted.  No need then for the Essex.
Back to top
 
Thank User For This Post  
IP Logged
 
jasonB
Re: What flange to use
Reply #8 - Nov 4th, 2004, 4:41pm
 
Thanks for the comments guys, I was a bit worried about the possibility of scale on the inside of the cylinder, it's in a hard water area (Epsom, Surrey).

Will have a word with the client and see what he wants to do, Although I have replaced a couple of cylinders I tend to stear clear of this type of work.

Jason