Baxi combi instant 105e flame failure (Read 27550 times)
bris
GDPR opt-out









Baxi combi instant 105e flame failure
Apr 2nd, 2008, 9:18pm
 
Hi I have a baxi combi instant 105e which when turned on goes to flame failure almost instantly. Ive managed to eliminate the pcb as the problem so took it apart to see if the fan was working which it was. While the cover was off the boiler worked with no problems. When i put the cover on again it still worked but when I tightened the screws to create a seal in the chamber it cut out and stopped working again. loosen the screws again and it works again possibly letting some air in keeps it working but again tighten the screws and fails. Hopes this makes sense to someone and maybe someone has hsd a similar problem, thanks for looking.
Back to top
 
 
IP Logged
 
lovejoy
GDPR opt-out









Re: Baxi combi instant 105e flame failure
Reply #1 - Apr 2nd, 2008, 10:58pm
 
make sure the flue intake is clear check the venturis follow the 2 silacone tubes from the air presure switch to the flue remove the tubes those are the venturis inside the flue make sure the heat exchanger is clear and not part blocked so as to stop the poc,s going through and clearing have seen this befor its usualy due to lack of servicing
Back to top
 
 
IP Logged
 
bris
GDPR opt-out









Re: Baxi combi instant 105e flame failure
Reply #2 - Apr 3rd, 2008, 12:14am
 
Thanks for the reply lovejoy but it was serviced around 4 weeks ago when and the the guy striped it down and cleaned everything out. I took it apart and checked just to make sure though. Any other suggestions appreciated.
thanks
Back to top
 
 
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Baxi combi instant 105e flame failure
Reply #3 - Apr 3rd, 2008, 12:17am
 
Yes get the guy back out, you really shouldn't be playing with the combustion side
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
lovejoy
Re: Baxi combi instant 105e flame failure
Reply #4 - Apr 3rd, 2008, 9:10pm
 
thescruff is correct, i stil think its down to the flue double check all flue connections next the air presure switch, as it worked sinse service if not has he got the tubes wrong way round on air pressure switch
Back to top
 
Thank User For This Post  
IP Logged
 
richrtr
Re: Baxi combi instant 105e flame failure
Reply #5 - Apr 8th, 2008, 8:57pm
 
Hi bris I have the same fault started 2 days ago , straight to flame fail only after a reset and the conbustion door loosely on will I get a flame,
so far new air stwitch £18 and new fan £ 75 still the same fault ,baxi say check flue etc !! done all that, it it pcb !!! but how does it know the door is letting in more air??? Gas valve ??? but it is lighting up ???
please let me know how you are getting on
Back to top
 
Thank User For This Post  
IP Logged
 
watty
Re: Baxi combi instant 105e flame failure
Reply #6 - Apr 8th, 2008, 11:20pm
 
hi richrtr. i'd say a pound to a penny its a dirty venturi,(in the flue elbow wher the two rubber pipes from the airswitch go to).when you loosen the cover you allow more air in to the chamber increasing the flow through the venturi. got to be that unless you have crossed the pipes when you put the new airswitch in Smiley(just checking).
Back to top
 
Thank User For This Post  
IP Logged
 
richrtr
Re: Baxi combi instant 105e flame failure
Reply #7 - Apr 9th, 2008, 5:03pm
 
Thanks very much for the reply, when I fitted the new fan it was the cowl and all,,,, so new clean venturi plus pipes and and aps, I have a complete one year old 105 for the doner for parts, just get her going for the mrs to have a shower again by letting air in..... via the combustion door, dont want to change the gas valve unless I really have too, but running out of ideas, could the gas valve be sticking????? and cant open against air pressure from the fan, with the door open air pressure less and valve can open ????
Back to top
 
Thank User For This Post  
IP Logged
 
lovejoy
Re: Baxi combi instant 105e flame failure
Reply #8 - Apr 9th, 2008, 5:38pm
 
nope this is a negative presure boiler, eaven if it was only a 1 year old dona id check the venturis its not the gas valve at all its somthing in that combustion chamber thats for sure
Back to top
 
Thank User For This Post  
IP Logged
 
lovejoy
Re: Baxi combi instant 105e flame failure
Reply #9 - Apr 9th, 2008, 5:45pm
 
just a thort now dont all laugh never seen it never tryed it but have u got the wires on the fan the rite way earth is easy but L and N if on wrong spades would the fan run wrong way lol dunno as i say
Back to top
 
Thank User For This Post  
IP Logged
 
richrtr
Re: Baxi combi instant 105e flame failure
Reply #10 - Apr 9th, 2008, 6:03pm
 
Checked fan cables via wireing diagram its ok!
as I am getting the spark with the door fully closed , surly I am proving the APS and fan as it going throuth the ignition sequence ? all I am then doing is allowing more air in getting the flame on then fully closeing the door , runs fine untill call for heat cancells then will not restart. All I have not changed is Pcb and gas valve. there is 230 v goes to gas valve so pccd must be ok ? is it the gas valve ?
Back to top
 
Thank User For This Post  
IP Logged
 
lovejoy
Re: Baxi combi instant 105e flame failure
Reply #11 - Apr 9th, 2008, 6:37pm
 
it is nothing to do with the gas valve as it wouldnt run with case cover off if it wont when on, the gas valve dont know u have the cover off, the fault is deffo somthing inside the combustion chamber u sure the fan is totaly free and running to speed check wires on aps commen  no & nc
Back to top
 
Thank User For This Post  
IP Logged
 
richrtr
Re: Baxi combi instant 105e flame failure
Reply #12 - Apr 9th, 2008, 7:12pm
 
Many thanks for your paitence, yes the fan seems to be running a full speed, the boiler its from was fully working when removed, it had only been fitted for a few weeks last year. so I must belived it ok and the aps too I,ve checked the venturi its clean. whats the chance of this fan and venturi beeing duff and my one? my boiler was good for 4 years before this fault, servied and cleaned every year. The baxi fault chart also says 230 v at gas valve yes = replace gas valve.
Back to top
 
Thank User For This Post  
IP Logged
 
lovejoy
Re: Baxi combi instant 105e flame failure
Reply #13 - Apr 9th, 2008, 7:27pm
 
says  PCB- A1 connector has 230v ac across terminals 2 & 4  = yes replace gas valve that is when no gas at burner if not 230v and no flame faliure flashing replace pcb
Back to top
 
Thank User For This Post  
IP Logged
 
richrtr
Re: Baxi combi instant 105e flame failure
Reply #14 - Apr 9th, 2008, 8:17pm
 
So are we saying replace pcb got one shall I fit it in the morning wife is moaning that its cold!!!!!
Back to top
 
Thank User For This Post  
IP Logged
 
richrtr
Re: Baxi combi instant 105e flame failure
Reply #15 - Apr 9th, 2008, 8:19pm
 
More to last,,,,,,,, but I am getting the flashing neon light,,,,,,,,,,,,,,, and I,m pulling out my hair================ come on the Bris how did you sort it ???????????? Huh
Back to top
« Last Edit: Apr 9th, 2008, 8:48pm by richrtr »  
Thank User For This Post  
IP Logged
 
lovejoy
Re: Baxi combi instant 105e flame failure
Reply #16 - Apr 10th, 2008, 7:04am
 
no im saying do those  tests to prove its not the gas valve, a dry joint on the board ? mmm how dose the board know when u have opend the chamber i still think its somthing in that combustion chamber, i have fit boilers from the box and aps dosnt work, the diaphram is moveing with cover off but not with it on i would deffo invest in a new aps for this boiler and double check tubes are rite, if the gas valve or board had gone it wouldnt work cover off or on, its you alowing air into it thats making the diffrence
Back to top
 
Thank User For This Post  
IP Logged
 