Baxi combi instant 105e flame failure (Read 27555 times)
lovejoy
GDPR opt-out









Re: Baxi combi instant 105e flame failure
Reply #17 - Apr 10th, 2008, 7:11am
 
thort , is the dona boiler a 105 he by any chance ?
Back to top
 
 
IP Logged
 
richrtr
GDPR opt-out









Re: Baxi combi instant 105e flame failure
Reply #18 - Apr 10th, 2008, 12:33pm
 
Thanks Lovejoy for all the help but fingers crossed I think I have sorted it!!!!!!!! Was about to change Gas valve as per book earth wire then pressure sensing pipe.... Followed that up to the brass conecttion in to the combustion chamber and then gently blow and sucked up and down it!!!! then went to doner boiler and did the same ...wow there is a diference in the amount of pressure that could be sucked down the clear pipe .S o changed them over and ,it now fires up with the door fully fitted. The newer one is a slightly different design ????
So did it wear or is the gas valve getting on abit four years and its tolerance for that in put from the pressure sensing pipe is a bit out. I wonder if changing the whole G.V would have did the trick. Fingers crossed now its ok. Cheesy Cheesy
Back to top
 
 
IP Logged
 
lovejoy
GDPR opt-out









Re: Baxi combi instant 105e flame failure
Reply #19 - Apr 10th, 2008, 3:03pm
 
as i sed at the start down to servicing that tube should be cleand with a air duster at each service glad its sorted was becomming a saga lol