RCD BS number
Dec 15th, 2010, 9:15pm
 
Hi

Have a wylex rcd with WRS80/2 written on it but couldnt find the bs number on it. Wondered if anyone new what the bs number would be for this rcd. It's in a split load board. Contacted wylex but they haven't got back to me.

Cheers
Back to top
 
 
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8814


Total Thanks: 108
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: RCD BS number
Reply #1 - Dec 15th, 2010, 9:46pm
 
BS61008 as that is a recent Wylex model I believe.

Older models would be BS4293.

Thats the only numbers for that type of  RCD - RCBO's etc would be a different matter.


Quote:
> BS 4293 : 1983 (1993)
Specification for residual current operated
circuit-breakers. (Replaced by BS EN 61008-
1: 1995, BS EN 61008-2-1: 1995 and BS
IEC 61008-2-2: 1990). This Standard
remains current

> BS 7071 : 1992 (1998)
Specification for portable residual current
devices

> BS 7288 : 1990 (1998)
Specification for socket-outlets incorporating
residual current devices. (SRCDs)

> BS EN 61008-1 : 1995 (2001)
Residual current operated circuit-breakers
without integral overcurrent protection for
household and similar uses (RCCBs)

> BS EN 61009-1 : 2004
Residual current operated circuit-breakers
with integral overcurrent protection for
household and similar uses (RCBOs)
Back to top
« Last Edit: Dec 18th, 2010, 6:44am by Lectrician »  

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
lenny
Re: RCD BS number
Reply #2 - Dec 15th, 2010, 10:24pm
 
That's great. Thanks for the info.

Much appreciated.
Back to top
 
Thank User For This Post  
IP Logged
 
The_Trician
Trade Member
*****
Offline


Posts: 7721


Total Thanks: 8
For This Post: 0


Gender: male

Trade: Electrician



Re: RCD BS number
Reply #3 - Dec 16th, 2010, 12:18pm
 
Back to top
« Last Edit: Dec 18th, 2010, 6:45am by Lectrician »  

Thats the trouble with a colostomy - you can never find the shoes to match the bag.......
Thank User For This Post  
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8814


Total Thanks: 108
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



RCD BS number
Reply #4 - Dec 18th, 2010, 6:50am
 
In the interest of keeping the forum helpful and informative, off topic replies have been pruned and are residing in the Removed Content Board.  Only moderators have access to this.
Back to top
« Last Edit: Dec 18th, 2010, 6:54am by Lectrician »  

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
Page Index Toggle Pages: 1
Send Topic Print