Welcome, Guest. Please Login or Register
Welcome To Ask The Trades!
Apr 16th, 2024, 10:44pm
Quote: Why is the time of day with the slowest traffic called rush hour?


Page Index Toggle Pages: 1
Send Topic Print
Hardcore (Read 2910 times)
JohnD
GDPR opt-out









Hardcore
Oct 26th, 2011, 8:51am
 
What type of hardcore should I need under a concrete garage floor, and come to that a kitchen floor? Specifications just say 'hardcore free of Hardcore to be of approved broken brick or similar approved, free from wood plaster or other deleterious matter.'

Not sure what to specify as my local builders merchants don't do broken brick.  I guess hoggin isn't suitable.

Mot 1?    

Thanks

John D
Back to top
 
 
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: Hardcore
Reply #1 - Oct 30th, 2011, 12:44am
 
Almost every builders merchant will be able to supply something to meet MOT Type 1. Even BnQ and ebay sell it at a price.  It can be made of different materials but I believe the best is made from crushed limestone. Sometimes it's made from crushed recycled concrete or road scalpings. If it's from a reputable source and they say it's MOT Type 1 is should be ok. MOT is a bit easier to level and compact than a load of old bricks and rubble.

http://www.pavingexpert.com/subbase.htm#unbound

A proper job might have a layer of sand on top and then a DPM/plastic sheet before conc is poured. Even if you don't need a DPC DPM the plastic stops water running out of the concrete and helps maintain the right ratio while it sets.  
Back to top
« Last Edit: Oct 30th, 2011, 9:23am by CWatters »  
Thank User For This Post View members image gallery  
IP Logged
 
Joiner
Trade Member
*****
Offline

Ask The Trades
Posts: 2063


Total Thanks: 7
For This Post: 0


Bridgnorth, Shropshire, England
Bridgnorth, Shropshire
England


Trade: Joiner

Re: Hardcore
Reply #2 - Oct 30th, 2011, 5:49am
 
"Even if you don't need a DPC the plastic stops water running out of the concrete and helps maintain the right ratio while it sets."

Shouldn't that be DPM? A typo methinks. Rare for you.



In older buildings without a DPC (Damp Proof Course) it can cause problems that aren't easily cured because moisture is directed towards the walls.

Aggregate will stop ground moisture rising into the slab - as long as the water table isn't above the height at which it finishes, of course!
Back to top
« Last Edit: Oct 30th, 2011, 6:00am by Joiner »  
Thank User For This Post View members image gallery  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: Hardcore
Reply #3 - Oct 30th, 2011, 9:22am
 
oops yes meant DPM.

Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
Joiner
Trade Member
*****
Offline

Ask The Trades
Posts: 2063


Total Thanks: 7
For This Post: 0


Bridgnorth, Shropshire, England
Bridgnorth, Shropshire
England


Trade: Joiner

Re: Hardcore
Reply #4 - Oct 30th, 2011, 6:31pm
 
Grin
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
Page Index Toggle Pages: 1
Send Topic Print