Welcome, Guest. Please Login or Register
Welcome To Ask The Trades!
Apr 25th, 2024, 11:47am
Quote: Depression is merely anger without enthusiasm.


Page Index Toggle Pages: 1
Send Topic Print
Freezing cold heated towel rails (Read 1993 times)
Allyshouse
GDPR opt-out









Freezing cold heated towel rails
Feb 25th, 2013, 7:10pm
 
We have recently converted our utility room to a bathroom. (Bungalow) previously no rads in utility and we now have two heated towel rails. Only they aren't heating! Previously were Luke warm but now freezing. It's a camray 5 fired boiler and pumpmaster Titan pressurised cylinder. Anyone give me any clues as to where to start?
Back to top
 
 
IP Logged
 
Headrush
Trade Member
*****
Offline

Ask The Trades
Posts: 147


Total Thanks: 10
For This Post: 0


Nottingham, United Kingdom
Nottingham
United Kingdom

Gender: male

Trade: Plumber

Re: Freezing cold heated towel rails
Reply #1 - Feb 25th, 2013, 7:43pm
 
Make sure there is adequate pressure in the system and it's off. Then bleed the air from the top's of the towel rails, they are notorious air traps. Top up the system pressure when cold if necessary to 1 bar. Also check that the rad valves are open enough, one may be set for balancing and may need opening a quater turn or so.