Leaking stop tap just above concrete floor (Read 5396 times)
kamog
GDPR opt-out
Leaking stop tap just above concrete floor
Mar 19
th
, 2013, 9:29am
The brass stop tap for the house will not close properly so normally I would not hesitate to shut off supply in the road, undo internal tap and replace washer. However 1st problem is the stop tap in the road serves 5 other houses and Welsh Water have told me I must not turn off the road stop tap as it is an offence to interfere with other people’s water supply. Only they can do it having giving proper advance legal notice to affected properties. I’d just talk to neighbours and get on with job but one will protest so it has to be done the ‘proper’ way. The next problem is that although WW say they will deal with temporary isolation at agreed time I am only allowed 15 mins to complete the job. If the job extends there could be £100’s fee depending on circumstances. In no way will WW come into the property to help.
I intend to have a complete new brass stop tap with compression fittings to hand if washer changing is not quick and easy but if the existing olive on the supply side pipe does not look too good I’d have to shorten the pipe. Next problem is the pipe has a curve where it comes up through the concrete floor and maybe there will not be enough straight pipe left. The tap is in a corner fairly close to wc so it’s difficult to judge the situation. Would you think it would be better and quicker if I need to cut off the old olive to use a Speedfit tap. I’d have steel wool to hand to do a thorough polish-up of the pipe of course. Thing is I have very little experience of using Speedfit with copper pipe although from playing around with a few bits it seems very good. Is it reliable long term?
If there is a leak that I can’t stop are there any emergency products which can be applied to the leak? Would the choice of emergency product differ for brass tap/and Speedfit?
Back to top
IP Logged
CWatters
Super Member
Offline
"Daddy fick it" says James
Posts: 5150
Total Thanks: 58
For This Post: 0
Gender:
Re: Leaking stop tap just above concrete floor
Reply #1 -
Mar 19
th
, 2013, 5:19pm
Not sure about the rules but perhaps consider fitting your own external stopcock using something like this to avoid having to turn off the main one...
http://www.jewson.co.uk/tool-hire/plumbing-equipment/pipe-freezing/
Back to top
IP Logged
Headrush
Trade Member
Offline
Ask The Trades
Posts: 147
Total Thanks: 10
For This Post: 0
Nottingham
United Kingdom
Gender:
Trade: Plumber
Re: Leaking stop tap just above concrete floor
Reply #2 -
Mar 19
th
, 2013, 8:58pm
Easy fix in my opinion would be to shut of the faulty cock as best you can and fit a new one above it then open the old one, remove the head and forget about it.
You might have to work with water leaking past the old stopcock, just use plenty of old towels and work quick
Back to top
IP Logged
cumbriahandyman
GDPR opt-out
Total Thanks: 10
For This Post: 0
Re: Leaking stop tap just above concrete floor
Reply #3 -
Mar 20
th
, 2013, 6:54am
Do it at night or early morning while neighbours are sleeping.
Back to top
IP Logged
londonman
Trade Member
Offline
I love YaBB 1G - SP1!
Posts: 1697
Total Thanks: 13
For This Post: 0
Malvern
United Kingdom
Trade: Cabinet Maker
Re: Leaking stop tap just above concrete floor
Reply #4 -
Apr 3
rd
, 2013, 11:58pm
Do you know one will protest or just guessing? I'd go speak to them and explain the situation.....sweeten with beer/tea/kiss/whatever.
Back to top
Would all Third Party Apologists kindly mind their own business .....
IP Logged
woodsmith
Global Moderator
Trade Member
Author
Offline
Posts: 4395
Total Thanks: 135
For This Post: 0
Gender:
Trade: Joiner
Re: Leaking stop tap just above concrete floor
Reply #5 -
Apr 4
th
, 2013, 8:40am
I would be very wary of using Speedfit on old pipe, the pipe needs to be perfect to make a good seal, any marks on the pipe and you would create yourself a whole raft of problems.
If you can find a stop tap identical to the existing one you could unscrew the whole tap assembly and replace it as a unit rather than just trying to swap the washer which may not be the whole problem.
Back to top
IP Logged
thescruff
Global Moderator
Trade Member
Author
Offline
Who said plumbing was
easy.
Posts: 6037
Total Thanks: 147
For This Post: 0
Gender:
Trade: Plumber
Re: Leaking stop tap just above concrete floor
Reply #6 -
Apr 4
th
, 2013, 9:40am
Dig a hole and expose the pipe before it enters your property.
Cut pipe live and fit a stopcock.
Plumbers doit underwater, so you don't get wet.
Back to top
IP Logged
Pages: 1
(Moderator: thescruff) - (Moderator Group: Board Moderator)
<
Previous Topic
|
Next Topic
>
Ask The Trades
›
DIY Forum
›
Plumbing Questions
› Leaking stop tap just above concrete floor
Forum Jump »
Home
» 10 most recent Posts
» 10 most recent Topics
DIY Forum
- Electrical Questions
- Plumbing Questions ««
- Carpentry Questions
- Building Questions
- Painting, Decorating & Tiling Questions
- Alarms, Phones, Aerials, CCTV & Datacomms
Public Forum
- Just Talk
- Humour
- The Forum
- Trade Applications
Ask The Trades
» Powered by
YaBB 2.3
!
YaBB
© 2000-2008. All Rights Reserved.