Commission boiler before central heating finished
Oct 1st, 2014, 6:17am
 
Hello, just installing new greenstar 24i junior on a project build, just wanted to know if I can commission boiler without central heating being finished, not rushing the project but would like to get hot water on, got isolating  valves in flow and return.
thanks.
Back to top
 
 
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Commission boiler before central heating finished
Reply #1 - Oct 1st, 2014, 10:01am
 
Wouldn't advise it unless you can put a couple of rads into circulation.

Had you installed an Intergas boiler you could have run it as a water heater or heating only
Back to top
« Last Edit: Oct 1st, 2014, 10:02am by thescruff »  
Thank User For This Post View members image gallery  
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8814


Total Thanks: 109
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: Commission boiler before central heating finished
Reply #2 - Oct 3rd, 2014, 10:20pm
 
As scruff says, rads are needed to "ditch" heat once your heat exchanger has finished heating your DHW.