British Gas Boiler 532/i (Worcester) (Read 3092 times)
Francois
GDPR opt-out









British Gas Boiler 532/i (Worcester)
Nov 13th, 2014, 9:59am
 
Hi,  I have a problem with my 3 year old British Gas Boiler 532/i  (Worcester).
I keep getting an "ERR" code on the LCD display. (no other codes)

The pressure gauge is just above 2.5 Bar, if I reduce the pressure to 1.5 (as it used to be) the boiler cuts out until I add more pressure.
I have reduced the Temp to about 60 c    , any higher and the pressure goes up to about 2.5 again.

anyone got any thoughts before I call British Gas ?

Added to post:-  I  have wondered if the pressure gauge on the boiler is reading the correct pressure as it used to loose pressure slightly over a couple of months, but now it seems to gain pressure!
Back to top
 
 
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: British Gas Boiler 532/i (Worcester)
Reply #1 - Nov 20th, 2014, 5:11pm
 
I'm not a plumber but..

If the pressure goes up a lot as the system heats up that usually means there is a fault with the expansion vessel. Could need recharging or replacing.  

The expansion vessel usually has a car tyre type valve on them. If water comes out when that's depressed (briefly) then it's faulty.  

Perhaps see also..
https://www.youtube.com/watch?v=SNULc5fhY28

I'm not sure what ERR means.

Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: British Gas Boiler 532/i (Worcester)
Reply #2 - Nov 20th, 2014, 7:02pm
 
Thanks CW meant to reply to this thread and forgot after all that birthday wine.  Cool

The err dosen't mean a lot on its own is there more to the code.

Can you post the GC number on the data plate as there's several variations
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
Francois
Re: British Gas Boiler 532/i (Worcester)
Reply #3 - Nov 22nd, 2014, 9:35am
 
Hi Thanks for replying,  I'll get to it as soon as I can...I'm away for the weekend.