22mm High Temperature Non Return Valve
Jan 14th, 2017, 3:00pm
 
I have a site with several sterilisers installed.  They have a 15mm chromed pipe outlet for the waste which is opened once a day, ditching 85°C water.  Currently, they all have the 15mm pipe terminating into a 22mm overflow waste non return valve, and these fail regularly.  The 22mm overflow pipe leaving the non return valve also overheats and bows.

This is the part:

...
http://www.plumbcenter.co.uk/product/mcalpine-convalve-in-line-non-return-valve-...

It seems to me that a metal version would be better, to cope with the heat, and 22mm metal pipe, not overflow.  The overflow eventually terminates into the 1.5" wastes, and these are not affected by the hot water.

Any ideas on the best way forward?

Back to top
 

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: 22mm High Temperature Non Return Valve
Reply #1 - Jan 17th, 2017, 6:59pm
 
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8814


Total Thanks: 108
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: 22mm High Temperature Non Return Valve
Reply #2 - Jan 19th, 2017, 6:05pm
 
I'm not sure they are going to work on the near no pressure of an overflow/drain from a steriliser.  1m head maximum.
Back to top
 

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: 22mm High Temperature Non Return Valve
Reply #3 - Jan 19th, 2017, 6:53pm
 
Presumably you can't use an air gap to prevent back flow because air must not get back in either?

1m head of water is about 1.4psi.

Google found these..

http://www.tamo.co.uk/products/valves-regulators/check-valves

http://www.tamo.co.uk/uploads/products/20100216034318-200series.pdf

Says they can do cracking pressures down to 0.1psi and temperatures up to 288C.

I think in this situation I'd explain the problem to a company like that and let them decide if they can warranty their check valves for the application.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: 22mm High Temperature Non Return Valve
Reply #4 - Mar 17th, 2017, 10:43am
 
Hep v° trap should do the job