If you have a run of kitchen appliances (fridge/dishwasher etc) underneath a worktop, is there a best practice/legislation for supplying power to them?

Do you put the power sockets behind the appliances?  Or do you have an unswitched socket behind the appliance fed from a wall-mounted switch located above the worktop ?

TIA
Back to top
 

Would all Third Party Apologists kindly mind their own business .....
Thank User For This Post View members image gallery  
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8814


Total Thanks: 108
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: Powering kitchen large appliances - best practice
Reply #1 - Mar 11th, 2017, 9:49am
 
A socket in an adjacent cupboard is my preference.  If there was three in a row, that may prove tricky.  You could then install an FCU above the counter, and either a socket directly behind the appliance, or a flex outlet.  A flex outlet is preferred by the NICEIC as you then have the fuse accessible in the FCU.  Most will put a socket in though, so as not to have to cut off the plug.
Back to top
 

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
londonman
Trade Member
*****
Offline

I love YaBB 1G - SP1!

Posts: 1697


Total Thanks: 13
For This Post: 0


Malvern, United Kingdom
Malvern
United Kingdom


Trade: Cabinet Maker

Re: Powering kitchen large appliances - best practice
Reply #2 - Mar 11th, 2017, 1:15pm
 
Thanks, Lec.  I like the idea of an FCU above and a flex outlet below as it then is a straight run picking up the sockets along the way.