Quote: I intend to live forever........So far, so good...


Page Index Toggle Pages: 1
Send Topic Print
Drips with brown stains from manifold (Read 2598 times)
Overrunning Project
Junior Member
**
Offline

Ask The Trades
Posts: 16


Total Thanks: 0
For This Post: 0



Drips with brown stains from manifold
Mar 22nd, 2017, 9:26pm
 
Hi

We are 11 months into a 6 month project.  The Under Floor Heating has been in about 5 weeks.  Recently the builder has turned the heating up to dry plaster board and the house.  I went round tonight and there is a constant drip that leaves a brown stain from two of the manifold connectors.
Should I be worried?
Thanks

Image 5

Image 7
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
Headrush
Trade Member
*****
Offline

Ask The Trades
Posts: 147


Total Thanks: 10
For This Post: 0


Nottingham, United Kingdom
Nottingham
United Kingdom

Gender: male

Trade: Plumber

Re: Drips with brown stains from manifold
Reply #1 - Mar 23rd, 2017, 9:45am
 
The two nuts beneath the dripping connector need to be tweaked up, perhaps just a quarter turn. If that doesn't work, they will have to be disconnected and inspected. It's possible there are no sleeve inserts inside the plastic pipes, a common mistake..
Back to top
 
Thank User For This Post  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: Drips with brown stains from manifold
Reply #2 - Apr 5th, 2017, 3:40pm
 
Once it's sorted make sure you put some corrosion inhibitor such as Fernox F1 in the system. The amount required depends on the volume of the system and you may need more than one bottle. Usually too putting in slightly too much is safer than not enough.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Drips with brown stains from manifold
Reply #3 - Apr 7th, 2017, 8:42am
 
To be fair you need to tell the builder or whoever installed it to sort it.

Is that underfloor heating pipe or plastic water pipe. ?
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
Page Index Toggle Pages: 1