Sep 1st, 2017, 3:53pm
 
Hi all

I've got an issue with a persistent immersion heater issue which I think may be related to something other than the heater itself. I might add that I live on a narrowboat, but that the electric supply is normal mains as i'm hooked up to a shoreline. The immersion heater itself is a 1kw type.

In September of last year my immersion heater failed (I came home to find breaker tripped on my consumer board and the main breaker on the shoreline post). After checking to see whether it was the thermostat (it wasn't), I replaced the immersion heater element and all was good, no issues.

Fast forward to April of this year, the new immersion heater failed in exactly the same manner. I bought a new multimeter and diagnosed a ground fault on the immersion heater, so replaced the heater once more for new. This lasted until the weekend where the same problem has developed, only this time I was there when the heater tripped out the breakers.

The only other thing of possible relevance is that I have an electronic timer which plugs into the mains socket, to which I then plug the immersion heater into. This of course then turns on the immersion heater for a few hours each morning and afternoon.

My concern is that there is some issue which is causing the heating element to fail, since it seems unlikely that I would have 2 elements fail in relatively quick succession.

Is there anything anybody can suggest I do? I'm thinking i'll replace the wiring from element to plug, on the assumption that the cable may have an issue?

Thanks in advance!!
Back to top
 
Thank User For This Post  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Immersion Heater repeated failure
Reply #1 - Sep 1st, 2017, 9:36pm
 
What is failing the element or the stat.

Is the element permanently in water.
Back to top
« Last Edit: Sep 1st, 2017, 9:39pm by thescruff »  
Thank User For This Post View members image gallery  
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8814


Total Thanks: 108
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: Immersion Heater repeated failure
Reply #2 - Sep 2nd, 2017, 7:53am
 
What is your water source?  There are titanium elements available.  Some tanks can have sacrificial anodes fitted, usually magnesium.
Back to top
 

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
scotspark
Trade Member
*****
Offline

mmmmm it's gonna cost
you!!
Posts: 3074


Total Thanks: 10
For This Post: 0


scotland, Scotland
scotland
Scotland

Gender: male

Trade: Electrician



Re: Immersion Heater repeated failure
Reply #3 - Sep 3rd, 2017, 4:09pm
 
Sounds like electrolytic action corroding the elemen
Back to top
 

brown to red and blue to f****&&&&ommited!!!!!!!!!!!!!!!!!!!!!!!!!!!
Thank User For This Post View members image gallery  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: Immersion Heater repeated failure
Reply #4 - Sep 4th, 2017, 2:06pm
 
Quote:
breaker tripped on my consumer board and the main breaker on the shoreline post


Sorry of this is a daft question but are you sure the immersion elements are failing?

Does the breaker on your board supply anything else? You mentioned a plug so is the immersion element plugged into a circuit that feeds other outlets?

 

Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
The_Trician
Trade Member
*****
Offline


Posts: 7721


Total Thanks: 8
For This Post: 0


Gender: male

Trade: Electrician



Re: Immersion Heater repeated failure
Reply #5 - Sep 4th, 2017, 6:15pm
 
Could be a spike when the plug-in timer switches off.

You could try the heater without the timer for a period if practical (you'd obviously have to stay with it to see if it worked ok)
Back to top
 

Thats the trouble with a colostomy - you can never find the shoes to match the bag.......
Thank User For This Post  
IP Logged
 
Charmwah
Newbie
*
Offline

Ask The Trades
Posts: 4


Total Thanks: 0
For This Post: 0



Re: Immersion Heater repeated failure
Reply #6 - Sep 5th, 2017, 9:54am
 
Hi all

Thanks for your responses. To answer the queries:

* I'm diagnosing a ground failure on the element itself.
* The element is permanently in water.
* The element type is an Ecotherm HE111A (available at www.heatrodshop.com) and uses an alloy element, so very unlikely to have corroded so quickly.
* The water source is my water tank (approximately 250l capacity), which is then filled manually from a standpipe on shore.
* The breaker on the consumer board only supplies one double plug socket. The other socket is in use by my battery charger (Sterling type, 40A smart charger). This charge is used to smart charge my 2 120Ah leisure batteries. I would note that this is not a new addition, and has been used on the boat for the last 5 years without any issue, until recently of course.
* The trip occurred when the timer switched the immersion heater on, not when the timer was switching the heater off.

I'm wondering whether there could be anything else at fault, such as the wiring having a split, or something else which could cause a power surge and blow the element?

Thanks again for your time all!
Back to top
 
Thank User For This Post  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: Immersion Heater repeated failure
Reply #7 - Sep 6th, 2017, 8:33pm
 
Re: "I'm diagnosing a ground failure on the element itself."

They appear to have a 12 month warranty so would be interesting to see what the manufacturer says.


Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
Charmwah
Newbie
*
Offline

Ask The Trades
Posts: 4


Total Thanks: 0
For This Post: 0



Re: Immersion Heater repeated failure
Reply #8 - Sep 7th, 2017, 7:51am
 
I called and they've asked first for photos of the element that i've removed. My guess is that they'll eventually ask for the element to be returned for further testing.

I'm not calling into question the reliability of the element, and i'm happy to have any shortcomings of the system shown up. When I spoke to them they suggested that the element may have been dry, but since my element is in the bottom of the tank, and the system is pressurized so that as soon as any water leaves the system the pump kicks in, I can't see how it could have run dry without my knowing about it...?
Back to top
 
Thank User For This Post  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Immersion Heater repeated failure
Reply #9 - Sep 7th, 2017, 2:20pm
 
That was my first thought, Is there a chance the cylinder is full of scale.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
Charmwah
Newbie
*
Offline

Ask The Trades
Posts: 4


Total Thanks: 0
For This Post: 0



Re: Immersion Heater repeated failure
Reply #10 - Sep 12th, 2017, 12:23pm
 
To respond specifically to thescruff's comment, No the tank isn't full of scale, no issue there at all.

After further conversations with the element manufacture i've been sent a 3rd element to try out...