CU Layout
Apr 12
th
, 2004, 11:10pm
Ok ello ello this is cool , anyway enough of that HIT ME!
CU Layout
I have to have to CU's cant do split or single none that ting ok!
I got to MK SENTRY CU one with RCD one with Isolater
FIRST SET UP WITH RCD
1. Down Stairs Ring(32A)
2. Kitchen has three seperate radial legs what to do with them? dont want to destroy kitchen which is only way to put them on ring.(2*16A)???
3. Shower Electric 10.5kw(50A)
SECOND WITH ISOLATER
4. Up stairs Lighting (6A)
5. Down stairs Lighting (6A)
6. Boiler(6A)
7. Alarm / Security Lights(6A)
8. Up stairs Ring(32A)
Problem i got is the kitchen sockets what RCD Rating should i use? ad's to 114A's i think anyhow tell me what you think
Back to top
IP Logged
Pro-Spark
GDPR opt-out
Re: CU Layout
Reply #1 -
Apr 12
th
, 2004, 11:20pm
Did I read that right that you have 3 radials on 2 mcb's
Tony
Back to top
IP Logged
al-yeti
Guest
Re: CU Layout
Reply #2 -
Apr 12
th
, 2004, 11:58pm
not really the radials are on the kitchen at present and everything else will be new as i wont be touching the the kitchen for a while, so there are 6 sockets in total all running from one fuse somewhere via junction box's trouble is i cant put them into a ring so not sure what to do with them???????worse case i will have to chase out the kitchen walls which are a flat roof with no ceiling access.
What about the rest? espcially RCD rating to what i gave
Back to top
IP Logged
plugwash
Administrator
Offline
I love YaBB 1G - SP1!
Posts: 1383
Total Thanks: 0
For This Post: 0
Trade: Not Specified
Re: CU Layout
Reply #3 -
Apr 13
th
, 2004, 10:44pm
sockets in any form of radial no matter how it spurs can be put on a 20A breaker if the cable is 2.5mm
normally you would use something like a 80A current rating 30ma trip rcd
generally i would say that all downstairs sockets should be on the rcd expect possibly one specifically for the freezer
whether you put the upstiars sockets on a rcd is your choice
Back to top
IP Logged
scotspark
Trade Member
Offline
mmmmm it's gonna cost
you!!
Posts: 3074
Total Thanks: 10
For This Post: 0
scotland
Scotland
Gender:
Trade: Electrician
Re: CU Layout
Reply #4 -
Apr 15
th
, 2004, 1:37am
as plug said bout kitchen on 20A mcb but i'd put all sockets on rcd personally
Back to top
brown to red and blue to f****&&&&ommited!!!!!!!!!!!!!!!!!!!!!!!!!!!
IP Logged
LSpark
Global Moderator
Trade Member
Author
Offline
Posts: 8069
Total Thanks: 3
For This Post: 0
London, UK
United Kingdom
Gender:
Trade: Electrician
Re: CU Layout
Reply #5 -
Apr 15
th
, 2004, 11:42pm
Not sure how you can run 2.5 radial at 20A, if its installed in thermaly insulated wall in or out of conduit, max is 18.5A
.
Back to top
IP Logged
Pages: 1
(Moderator: Lectrician) - (Moderator Group: Board Moderator)
<
Previous Topic
|
Next Topic
>
Ask The Trades
›
DIY Forum
›
Electrical Questions
› CU Layout
Forum Jump »
Home
» 10 most recent Posts
» 10 most recent Topics
DIY Forum
- Electrical Questions ««
- Plumbing Questions
- Carpentry Questions
- Building Questions
- Painting, Decorating & Tiling Questions
- Alarms, Phones, Aerials, CCTV & Datacomms
Public Forum
- Just Talk
- Humour
- The Forum
- Trade Applications
Ask The Trades
» Powered by
YaBB 2.3
!
YaBB
© 2000-2008. All Rights Reserved.