2 or 3 core armoured?
May 25th, 2004, 7:27pm
 
I need to run armoured cable underground to my garage/workshop. Can I use 2 core and use the armour as the earth, or do I need to run three cored? If It is the three cored, which colours should be used for live neutral and earth in a single phase installation? Thanks in anticipation!
Elliott.
Back to top
 
Thank User For This Post  
IP Logged
 
plugwash
Administrator
*****
Offline

I love YaBB 1G - SP1!

Posts: 1383


Total Thanks: 0
For This Post: 0



Trade: Not Specified

Re: 2 or 3 core armoured?
Reply #1 - May 25th, 2004, 7:34pm
 
2 core is allowed but i would strongly reccomend 3 core especially for amuters (who may make an imperfect job of armour termination)

it is normal to use the yellow core as earth and this should be sleeved with green/yellow sleeving

it is normal to use blue as neutral and this technically should be sleeved black but virtually noone bothers and black sleeving is almost impossible to get
Back to top
 
Thank User For This Post WWW plugwash plugwash 107767391 peter_m_green_zyworld_com plugwash  
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8814


Total Thanks: 108
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: 2 or 3 core armoured?
Reply #2 - May 25th, 2004, 7:35pm
 
Red Live, Blue Neutral, Yellow Earth.

Always better to use a 3 core, although a 2 core can be used with the armour as an earth.

Depends on the size, current drawn, length of run etc to determine the Zs of the circuit to say 100% if using the armour is sufficient.  Best to stick to 3core really, but ensure you still earth the armour
Back to top
 

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
Elliott
Newbie
*
Offline

I love YaBB 1G - SP1!

Posts: 3


Total Thanks: 0
For This Post: 0



Re: 2 or 3 core armoured?
Reply #3 - May 25th, 2004, 7:40pm
 
Thank you! I did not expect such quick replies! OK so if I use 3 core, do I just earth the armour at the supply end, or should it be tied in at both ends?
Elliott.
Back to top
 
Thank User For This Post  
IP Logged
 
supersparky
Administrator
Trade Member
Author
*****
Offline


Posts: 6097


Total Thanks: 3
For This Post: 0


Gender: male

Trade: Electrician



Re: 2 or 3 core armoured?
Reply #4 - May 25th, 2004, 7:46pm
 
both, prefrably(thank you lectrician), and obviously use the yellow core as earth  Grin

ss
Back to top
« Last Edit: May 25th, 2004, 10:15pm by supersparky »  
Thank User For This Post WWW  
IP Logged
 
Elliott
Newbie
*
Offline

I love YaBB 1G - SP1!

Posts: 3


Total Thanks: 0
For This Post: 0



Re: 2 or 3 core armoured?
Reply #5 - May 25th, 2004, 7:50pm
 
Thanks Guys! You have sorted out in minutes, what a couple of books, and numerous web pages have failed to help me with!
Very much appreciated!!!!
Elliott.
Back to top
 
Thank User For This Post  
IP Logged
 
LSpark
Global Moderator
Trade Member
Author
*****
Offline


Posts: 8069


Total Thanks: 3
For This Post: 0


London, UK, United Kingdom
London, UK
United Kingdom

Gender: male

Trade: Electrician



Re: 2 or 3 core armoured?
Reply #6 - May 27th, 2004, 2:05pm
 
just make sure to sleeve the yellow as earth with green and yellow stripped sleeving, then it complies with them nasty regulations!  Cheesy