Welcome, Guest. Please Login or Register
Welcome To Ask The Trades!
Apr 20th, 2024, 4:49pm
Quote: Why is the alphabet in that order? Is it because of that song?


Page Index Toggle Pages: 1
Send Topic Print
Outside Stand Pipe (Read 5080 times)
rabbit_rabbit
GDPR opt-out









Outside Stand Pipe
Jun 20th, 2004, 9:48am
 
My sister-in-law asked me what was involved in getting a water tap near her veggie patch, which is about 100 feet down her garden. I said I would ask the experts (who will probably tel me to get a plumber in to do it!).

Something like -

MDPE pipe buried, if so how deep does it have to be buried to prevent freezing? And what sort of connections at each end? Or forget the whole idea?

Many thanks for any comments

Ray
Back to top
 
 
IP Logged
 
HM
Super Member
*****
Offline

Chief Turd Polisher
Posts: 5072


Total Thanks: 0
For This Post: 0


Gender: male

Re: Outside Stand Pipe
Reply #1 - Jun 20th, 2004, 10:46am
 
You need the blue pipe for burial purposes. I don't know the legalities of this but I would have thought at least 6in down.

That trench will be your biggest job.

Andrew
Back to top
 

If you aren't always sure of the right answer don't take up a career in the bomb squad
Thank User For This Post  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Outside Stand Pipe
Reply #2 - Jun 20th, 2004, 11:29am
 
Pipe should be 11/2 spits down to prevent damage. Cry

Water regs say 750mm min.  Grin

Depending where you intended to connect it a stopcock, single check valve, and a means off draining the pipe out.

I would connect at a point where the mains enters the house an fit a seperate stopcock in the ground down the garden.

scruff
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
rabbit_rabbit
Re: Outside Stand Pipe
Reply #3 - Jun 20th, 2004, 11:41am
 
Andrew I think MDPE IS that blue piping.

Blimey Scruff water regs are as bad as IEE regs; 750mm is the same as buring swa (armoured) cable.

(a) Does it have to conform to the water regs if a check valve is used (which I know IS needed anyway)?

(b) were it buried only just below surface and drained at the end of each year (to prevent freezing) would that be OK. The idea of digging down 750 over some 100 feet fills me with awe, maybe have to hire a mini jcb.

Many thanks for your comments HandyMac and Scruff

RR
Back to top
 
Thank User For This Post  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Outside Stand Pipe
Reply #4 - Jun 20th, 2004, 12:02pm
 
RR you can use the mdpe as a hose pipe and connect it to an outside tap at the house, provided its not in sunlight.

You could also use speed fit the same way, or even a long garden hose.

Frost in this country is unlikely to reach more than 300mm. We fit pipes above ground lagged them, and then water proof the lagging, design is for -15c for an hour.

scruff
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
Page Index Toggle Pages: 1
Send Topic Print