CU ?
Aug 12th, 2004, 11:53am
 
Do you get problems with CU with just  a 80 amp RCD main incomer , or is it best to go for to go for split load CU, with RCD + main switch!
in case of trippin problems
Back to top
 
Thank User For This Post  
IP Logged
 
Beanzy
Re: CU ?
Reply #1 - Aug 12th, 2004, 12:33pm
 
Depends on supply type. But speccing a Consumer Unit up isn't really a DIY job.

On TT supplies best to have a 100mA RCD main. Split load are good for avoiding whole installation shut-down/ black-out just because the kettle goes dodgy or you splash water on a socket in the kitchen. Best ensure the sockets are protected by a 30mA RCD and any garage or outdoor supplies.

Bit more info on scenario would help. Once we have that then will probably want some more info on loads and characteristics of suppliers installation.
Back to top
 
Thank User For This Post  
IP Logged
 
rabbit_rabbit
Re: CU ?
Reply #2 - Aug 12th, 2004, 6:54pm
 
Giving a generalised answer to a generalised question I would always lean towards a split CU nowadays and rarely think twice about it. 100A main (on a 100A cut out) and a 63A or 80A 30mA RCD. If it's TT (overhead supply - yet more generalising!) then most certainly a 100A 100mA Main RCD).

I suspect the day will come when you will not be able to buy non split CU's and that would be a good thing.

RR
Back to top
 
Thank User For This Post  
IP Logged
 
The_Trician
Trade Member
*****
Offline


Posts: 7721


Total Thanks: 8
For This Post: 0


Gender: male

Trade: Electrician



Re: CU ?
Reply #3 - Aug 12th, 2004, 7:28pm
 
I prefer an enclosure full of RCBOs!

TT
Back to top
 

Thats the trouble with a colostomy - you can never find the shoes to match the bag.......
Thank User For This Post  
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8814


Total Thanks: 108
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: CU ?
Reply #4 - Aug 12th, 2004, 7:47pm
 
good call TT - not much more expensive if only one or two rings Smiley
Back to top
 

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
rabbit_rabbit
Re: CU ?
Reply #5 - Aug 12th, 2004, 8:16pm
 
lol TT - ya have to be right of course EVERY cct should have its own RCBO. Now let me see, each RCBO at £45, that's 10 cct that'll be £450 plus a new CU box, that'll be another £80, plus fitting ......"Err that will be £800 Mr. Bloggs".

I like it - as the yanks use to say "raise the ASP" (Average Selling Price) and THAT is JUST how ya do it!

Ray
Back to top
 
Thank User For This Post  
IP Logged
 
plugwash
Administrator
*****
Offline

I love YaBB 1G - SP1!

Posts: 1383


Total Thanks: 0
For This Post: 0



Trade: Not Specified

Re: CU ?
Reply #6 - Aug 12th, 2004, 10:32pm
 
if you are using rcbos you only rcd the stuff that needs it (either by regs or in your professional opinion)

i can't imagine you haveing more than 4 or 5 cuircuits that need to be rcd protected

it is a pricy option compared to a split CU though

while there is nothing in the wiring regs preventing a 30ma rcd as main incomer it may bring problems with stuff like fire alarm regs

Back to top
 
Thank User For This Post WWW plugwash plugwash 107767391 peter_m_green_zyworld_com plugwash  
IP Logged
 
LSpark
Global Moderator
Trade Member
Author
*****
Offline


Posts: 8069


Total Thanks: 3
For This Post: 0


London, UK, United Kingdom
London, UK
United Kingdom

Gender: male

Trade: Electrician



Re: CU ?
Reply #7 - Aug 13th, 2004, 5:14pm
 
yea your right plug, Fire alarms and Emergency Lighting have to not be run on the RCD and on it's own dedicated circuit.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
sparky_si-fi
Re: CU ?
Reply #8 - Aug 13th, 2004, 11:23pm
 
i love RCBO's as well

I have ran out of room on the re-wire I am doing at the mo so a small 4 way enclosure,100A isolator 6A CB for lights 32A RCBO for the socks and 16A CB for the immersion/central heating,

'bout 55 quid if memory serves me...
Back to top
 
Thank User For This Post  
IP Logged
 