imersion heater
Sep 11th, 2004, 10:47pm
 
Guys,
In my new house i have an Economy 7 hot water tank which is heated by two 3kw immersion heaters one at the top and one at the bottom.  Trawling through other forums I have now discovered that the bottom one is for the economy 7 heating and the top one is for on demand water. I would like to install a timer to switch the bottom heater on during the economy 7 hours as currently it is just controlled from a fused switch which is inconvenient as the cheap rate is in the middle of the night.  Will a standard 16A mechanical timer be sufficient (i assume that the max current drawn will be just over 13A for a 3kw heater, unless they draw more to start with?) or will I have to use the ones made specifically for economy 7 which seem to be about 3 times the price, is there a reason for this?
All help appreciated.
Back to top
 

We will fix it, we will fix it
Thank User For This Post  
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8814


Total Thanks: 108
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: imersion heater
Reply #1 - Sep 11th, 2004, 10:51pm
 
That sounds fine.  But, it should have been put on the switched board with your storage rads if you have them??  But, yep, what you suggest is fine, aslong as you set the times for 12 till 1, and 2 till 6, and keep the clock right, you will be fine Smiley
Back to top
 

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
Mice
Junior Member
**
Offline

pass me the BIG hammer

Posts: 69


Total Thanks: 0
For This Post: 0


Gender: male

Re: imersion heater
Reply #2 - Sep 11th, 2004, 11:00pm
 
Finally someone who seems to know what thy are talking about with regards to economy 7,  I have two boards in my study but whoever wired the house has not labelled any of the mcb's, so will the supply switch one of the boards on and off automatically?. the top immersion heater has in indicator on the switch so i know that it works during the day, how should i check to see that the economy 7 one only works at night as it will be expensive to leave on constantly if not setup correctly.
Back to top
 

We will fix it, we will fix it
Thank User For This Post  
IP Logged
 
plugwash
Administrator
*****
Offline

I love YaBB 1G - SP1!

Posts: 1383


Total Thanks: 0
For This Post: 0



Trade: Not Specified

Re: imersion heater
Reply #3 - Sep 12th, 2004, 1:52am
 
probablly best to replce the switch with one that has an indicator

as for the fuse boards can you follow the tails and figure out what the wiring before them is doing?

if not then you will have to test
Back to top
 
Thank User For This Post WWW plugwash plugwash 107767391 peter_m_green_zyworld_com plugwash  
IP Logged
 
Mice
Junior Member
**
Offline

pass me the BIG hammer

Posts: 69


Total Thanks: 0
For This Post: 0


Gender: male

Re: imersion heater
Reply #4 - Sep 12th, 2004, 5:32am
 
Good idea about the switch, Many thanks.
Back to top
 

We will fix it, we will fix it
Thank User For This Post  
IP Logged
 