Boiler needs reseting! (Read 5892 times)
gecko_101
Junior Member
**
Offline

I love YaBB 1G - SP1!

Posts: 6


Total Thanks: 0
For This Post: 0



Boiler needs reseting!
Nov 13th, 2004, 10:41am
 
Hi, my boiler needs reseting nearly every day.  It's a glowworm spacesaver and it powers a flowmax heatstore that heats the hot water and the central heating.  

I had a so-called heating engineer out yesterday, who serviced it, but could not find any faults.  This morning it failed to fire again.

Every time I press the reset button, it works OK, then some time later it trips again.

Any ideas,
Thanks
Dave
Back to top
 
Thank User For This Post  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Boiler needs reseting!
Reply #1 - Nov 13th, 2004, 10:58am
 
Can't say I know too much about this boiler, but it sounds like a pump over-run problem.

Check the pump is working, and time the over-run when the boiler switches off.

scruff

will try to find out a bit more in the meantime.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Boiler needs reseting!
Reply #2 - Nov 13th, 2004, 11:35am
 
which model is the boiler.

scruff
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
gecko_101
Junior Member
**
Offline

I love YaBB 1G - SP1!

Posts: 6


Total Thanks: 0
For This Post: 0



Re: Boiler needs reseting!
Reply #3 - Nov 13th, 2004, 11:39am
 
Hi, thanks

It's a KFB 50.  

One thing I have noticed is that when the boiler fires the electronic egnition takes about 30 second before the mail burner kicks in, I'm not sure if this is normal?

Dave
Back to top
 
Thank User For This Post  
IP Logged
 
gecko_101
Junior Member
**
Offline

I love YaBB 1G - SP1!

Posts: 6


Total Thanks: 0
For This Post: 0



Re: Boiler needs reseting!
Reply #4 - Nov 13th, 2004, 11:41am
 
hi,

to time when the overrun takes, is this the time after the programmer turns of the central heating pump?

dave
Back to top
 
Thank User For This Post  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Boiler needs reseting!
Reply #5 - Nov 13th, 2004, 12:10pm
 
the over-run if it has one will keep the pump running for several minutes after the boiler shuts down.

still trying to find info ( my son is out ) and it more his line, so hang in there.

scruff
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
gecko_101
Junior Member
**
Offline

I love YaBB 1G - SP1!

Posts: 6


Total Thanks: 0
For This Post: 0



Re: Boiler needs reseting!
Reply #6 - Nov 13th, 2004, 12:56pm
 
Hi,

It does have an over run, I will time it later.

Dave
Back to top
 
Thank User For This Post  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Boiler needs reseting!
Reply #7 - Nov 16th, 2004, 4:07pm
 
Hi gecko,

Not forgotten you, spoke to glowworm technical today, and they suggest it is either the overheat stat £23 ish or the thermostat £38 ish both plus fitting.

cost wise probably better to change both while the engineer is on site, about an hours work.

scruff
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
gecko_101
Junior Member
**
Offline

I love YaBB 1G - SP1!

Posts: 6


Total Thanks: 0
For This Post: 0



Re: Boiler needs reseting!
Reply #8 - Nov 17th, 2004, 4:45pm
 
Hi,

You've been a great help!

I will probably try to change these myself, I think I should be able to manage the job.  I'm assuming that I won't need to interfere with any of the gas components.

Dave
Back to top
 
Thank User For This Post  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Boiler needs reseting!
Reply #9 - Nov 18th, 2004, 8:58am
 
The overheat thermostat could be faulty but it
is just as likely that the appliance is actually overheating. Check
calibration of boiler thermostat, operation of pump overrun and that there
is an adequate bypass circuit.

scruff
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
gecko_101
Junior Member
**
Offline

I love YaBB 1G - SP1!

Posts: 6


Total Thanks: 0
For This Post: 0



Re: Boiler needs reseting!
Reply #10 - Nov 18th, 2004, 2:29pm
 
hmm...

well, there are radiators in the system without thermostatic valves, so these will act as a bypass?

I have not timed the overrun yet.

Dave
Back to top
 
Thank User For This Post  
IP Logged
 
Page Index Toggle Pages: 1
Send Topic Print