Dual Central Heating System (Read 4235 times)
DonR
GDPR opt-out









Dual Central Heating System
Oct 21st, 2013, 4:15pm
 
We already have a Combi Boiler which is only 12 months old and heats the rads and water perfectly. We have a large basement room into which I am planning to put a woodburner. The wooburner I have in mind can have a back boiler as part of the spec.
My question is: can the central heating system be set up so that when I want to run it off the gas I can but if I want to run it off the woodburner is there a way of shutting down the gas boiler and switching the CH system over to hot water supplied by the woodburner's back boiler?
Hope that makes sense - just to be clear, can I heat the rads and hot water in my house via two different boilers by switching from one boiler to the other when it suits me i.e switch the gas boiler off and the woodburner boiler on or vice versa.
Thanks fellas, hope someone can tell me it can be done.
Don.
Back to top
 
 
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 1


Gender: male

Trade: Plumber



Re: Dual Central Heating System
Reply #1 - Oct 21st, 2013, 5:42pm
 
it can be done with something like the dunsley neutraliser

http://www.dunsleyheat.co.uk/neutralizer.html

You do need to get an expert in though
Back to top
« Last Edit: Oct 21st, 2013, 5:43pm by thescruff »  
Thank User For This Post View members image gallery  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 1


Gender: male

Re: Dual Central Heating System
Reply #2 - Oct 21st, 2013, 9:33pm
 
What thescruff said. Essential you use an expert.

Wood burners are essentially uncontrolled devices. If the water in the back boiler starts to get too hot there is no automatic thermostat that will turn down the flames! This means all such installations have to be designed to fail safe, including in the event of a power cut. I believe this usually means at least some part of the system has to be gravity driven and there needs to be a dump rad to get rid of excess heat (eg if the stat or a power cut turns off any pumped part of the system). I may well be wrong on the detail as I'm not an expert!
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
woodsmith
Global Moderator
Trade Member
Author
*****
Offline


Posts: 4395


Total Thanks: 135
For This Post: 1


Gender: male

Trade: Joiner

Re: Dual Central Heating System
Reply #3 - Oct 22nd, 2013, 7:33am
 
I would check to see if this is really practical before spending a lot of money fitting this system. My concern is that wood burners are generally designed to produce hot water and maybe heat a radiator in a bathroom. You would need a very big wood burner to provide enough heat for full central heating. Then, unless the room is massive, it would produce too much heat in the room and make it unbearable.

We have a medium sized wood burner ( no back boiler) in a big room with vaulted ceilings and if we run it for long it soon gets the room too hot to be comfortable.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
londonman
Trade Member
*****
Offline

I love YaBB 1G - SP1!

Posts: 1697


Total Thanks: 13
For This Post: 0


Malvern, United Kingdom
Malvern
United Kingdom


Trade: Cabinet Maker

Re: Dual Central Heating System
Reply #4 - Jan 29th, 2014, 1:48pm
 
Isn't there also a possible issue as to how good the woodburner would be working in what is a mains pressured system?  Dunno...just guessing.

Back to top
 

Would all Third Party Apologists kindly mind their own business .....
Thank User For This Post View members image gallery  
IP Logged
 