Quote: How do you tell when you're out of invisible ink?


Page Index Toggle Pages: 1
Send Topic Print
Baxi 80e (Read 1862 times)
chrisjjones
GDPR opt-out









Baxi 80e
Aug 28th, 2016, 2:15pm
 
Hello I have a baxi combi 80e which fires on demand but wont stay on, once the flame has died (after approximately 10 seconds) the 30deg/flame failure light flashes. What possible causes are there for this that can be checked. I'm thinking it maybe the PCB. Undecided
Back to top
 
 
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 1


Gender: male

Trade: Plumber



Re: Baxi 80e
Reply #1 - Aug 29th, 2016, 10:59am
 
You should be getting a gasman to sort this.

Check the flame sensing electrode and the lead and make sure its all connected and in the right place, there are test you can do if you have the kit ( readings will be in the manual.

Worth checking the polarity for the electric supply to the boiler. Live should be 230Vac ish, Neutral 0v

PCB