Hi
We have just had some dimmer switches installed however when we turn them on there is a long delay before the lights switch on. There is also a large delay when you try to dim the lights.
Does anyone know what the problem is and how we could resolve this?
Thanks
Back to top
IP Logged
Natedog
Full Member
Offline
Ask The Trades
Posts: 347
Total Thanks: 9
For This Post: 0
Swindon
United Kingdom
Re: Dimmer Delay
Reply #1 -
Mar 25
th
, 2017, 2:37pm
What sort of light is it dimming?
Could be that the delay is a soothing capacitor or capacitive dropper in an led him or fitting that has to charge up / discharge and that's giving you the delay?
Back to top
IP Logged
Overrunning Project
Junior Member
Offline
Ask The Trades
Posts: 16
Total Thanks: 0
For This Post: 0
Re: Dimmer Delay
Reply #2 -
Mar 26
th
, 2017, 7:25am
Hi
Thanks for the reply.
They are dimming LED downlights.
Thanks
Back to top
IP Logged
Lectrician
Administrator
Trade Member
Author
Offline
Ask The Trades
Posts: 8815
Total Thanks: 109
For This Post: 0
Braunton, North Devon
United Kingdom
Gender:
Trade: Electrician
Re: Dimmer Delay
Reply #3 -
Mar 26
th
, 2017, 4:31pm
You are best using a dimmer recommended by the LED manufacturer. A short delay is normal.
Back to top
Need to post a picture? Click
HERE
for info!
IP Logged
Overrunning Project
Junior Member
Offline
Ask The Trades
Posts: 16
Total Thanks: 0
For This Post: 0
Re: Dimmer Delay
Reply #4 -
Mar 30
th
, 2017, 9:22pm
Hi
We have just had 3 dimmable spot lights fitted on the same circuit and their response time is perfect. I don't understand how the downlights take 3 -4 seconds to switch on however the 3 dimmable spot lights switch on immediately?
Thanks
Back to top
IP Logged
Lectrician
Administrator
Trade Member
Author
Offline
Ask The Trades
Posts: 8815
Total Thanks: 109
For This Post: 0
Braunton, North Devon
United Kingdom
Gender:
Trade: Electrician
Re: Dimmer Delay
Reply #5 -
Apr 1
st
, 2017, 6:50am
Different fittings? Different LEDs? Different dimmers? Getting the combo right is a challenge.
Back to top
Need to post a picture? Click
HERE
for info!
IP Logged
Overrunning Project
Junior Member
Offline
Ask The Trades
Posts: 16
Total Thanks: 0
For This Post: 0
Re: Dimmer Delay
Reply #6 -
Apr 7
th
, 2017, 5:10pm
The problem looks to be solved. I got another electrician round and he fitted the following - Aurora LED Dimming Module AU-DSP400X. It seems to work perfectly now.
Thanks for help
Back to top
IP Logged
Pages: 1
(Moderator: Lectrician) - (Moderator Group: Board Moderator)
<
Previous Topic
|
Next Topic
>
Ask The Trades
›
DIY Forum
›
Electrical Questions
› Dimmer Delay
Forum Jump »
Home
» 10 most recent Posts
» 10 most recent Topics
DIY Forum
- Electrical Questions ««
- Plumbing Questions
- Carpentry Questions
- Building Questions
- Painting, Decorating & Tiling Questions
- Alarms, Phones, Aerials, CCTV & Datacomms
Public Forum
- Just Talk
- Humour
- The Forum
- Trade Applications
Ask The Trades
» Powered by
YaBB 2.3
!
YaBB
© 2000-2008. All Rights Reserved.