Installing boiler to chimney wall? (Read 3041 times)
DtN72
Newbie
*
Offline

Ask The Trades
Posts: 3


Total Thanks: 0
For This Post: 0



Installing boiler to chimney wall?
Apr 16th, 2018, 12:16pm
 
Any gas safe plumbers out there? Can you help me with some advice, thanks.
Okay, my Worcester combi boiler needs moving. Someone suggested fixing it to the side of the chimney wall with the flue going into the chimney, so the escaping gas would go up the chimney. I have a wood burner that I use. My worry is the gas could be blown back into our house when the burner is not being used. It gets very windy where I live.
Also the outlet for the waste water from the boiler - he suggested channelling that into the soil pipe that comes down from my upstairs bathroom and also feeds off my downstairs washing machine, kitchen sink etc.
I would have thought that the boiler must be fitted to an external wall or at least the flue on an external wall. Shouldn't the waste from the boiler go out by a separate pipe. I'm not a plumber by any means, but this sounds dodgy to me. Undecided
Any suggestions? Is this person talking out of his bottom?
Thanks.
Back to top
 
Thank User For This Post  
IP Logged
 
Natedog
Full Member
***
Offline

Ask The Trades
Posts: 343


Total Thanks: 9
For This Post: 1


Swindon, United Kingdom
Swindon
United Kingdom


Re: Installing boiler to chimney wall?
Reply #1 - Apr 17th, 2018, 12:22pm
 
It's more than likely got a balanced flue - a pipe within a pipe that sucks fresh air in as well as vent the exhaust.  I don't think you'd be able to vent it into a chimney
Back to top
 
Thank User For This Post WWW View members image gallery  
IP Logged
 
woodsmith
Global Moderator
Trade Member
Author
*****
Offline


Posts: 4395


Total Thanks: 135
For This Post: 1


Gender: male

Trade: Joiner

Re: Installing boiler to chimney wall?
Reply #2 - Apr 17th, 2018, 6:20pm
 
The log burner should have a flue liner which runs up inside the chimney and you would not be able to cut into it so I think you have been given bad advice on that aspect of the job.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 1


Gender: male

Trade: Plumber



Re: Installing boiler to chimney wall?
Reply #3 - Apr 17th, 2018, 11:42pm
 
Ok the obvious first, you need a gassafe engineer to move and install the boiler to the regs.

The solid fuel burner should have a special liner depending on the existing stack, age and makeup.

You can buy boilers that will allow you to run the flue into the chimney with a separate inlet tube to provide the air intake but if the stack is already in use then not an option.

Boiler waste I assume you mean the condensate pipe, which can run into and plastic drain/soil pipe, However, the pipe from the safety valve/expansion vessel needs to be terminated where the public is not at risk
Back to top
« Last Edit: Apr 17th, 2018, 11:44pm by thescruff »  
Thank User For This Post View members image gallery  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: Installing boiler to chimney wall?
Reply #4 - May 2nd, 2018, 8:30pm
 
DtN72 wrote on Apr 16th, 2018, 12:16pm:
Is this person talking out of his bottom?


I think that's been answered Smiley
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
Page Index Toggle Pages: 1
Send Topic Print