Ceiling downlights (Read 5534 times)
Natedog
Full Member
***
Offline

Ask The Trades
Posts: 346


Total Thanks: 9
For This Post: 0


Swindon, United Kingdom
Swindon
United Kingdom


Ceiling downlights
Jun 10th, 2019, 12:31pm
 
One of the downlights in our bathroom has died.  Got a sneaky feeling all that's wrong is that I've either broken or pulled out one of the wires that comes from the bulb holder to the transformer when I was trying to get a blown bulb out that didn't want to play nicely.

Is there an easy way of removing the whole unit from the ceiling without causing damage?
Back to top
 
Thank User For This Post WWW View members image gallery  
IP Logged
 
Flashbang
Junior Member
**
Offline

I've been P'eeeeeeed
Posts: 117


Total Thanks: 0
For This Post: 0


Gender: male



Re: Ceiling downlights
Reply #1 - Jun 10th, 2019, 4:46pm
 
Hi
Usually ceiling spot lights are held in place to the ceilings upper surface by two sprung arms. These are held against the light fitting as its pushed up through the hole and spring out downwards and support the light fitting when its finally in place.  
Applying an even downward force on the lights rim should slowly allow the fitting to be eased out and the sprung arms forced upwards allowing the fitting to be completely removed.
Turn power off at mains then use something solid but thin to go between rim of light and ceiling carefully ease the fitting downwards. A couple of dinner table knives or a metal wallpaper scraper or if you have them a pair of 12 inch steel rules are ideal as they are thin but strong, but all can be used a levers.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: Ceiling downlights
Reply #2 - Jun 11th, 2019, 4:38pm
 
+1 although sometimes those springs can be darn strong and awkward. Mind your fingers.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
londonman
Trade Member
*****
Offline

I love YaBB 1G - SP1!

Posts: 1697


Total Thanks: 13
For This Post: 0


Malvern, United Kingdom
Malvern
United Kingdom


Trade: Cabinet Maker

Re: Ceiling downlights
Reply #3 - Jun 14th, 2019, 6:04am
 
And if you can manage to get one out without pulling away some of the plaster than you're a better man than me.

And if you can find one identical to replace it....you're very very lucky.

Back to top
 

Would all Third Party Apologists kindly mind their own business .....
Thank User For This Post View members image gallery  
IP Logged
 
Natedog
Full Member
***
Offline

Ask The Trades
Posts: 346


Total Thanks: 9
For This Post: 0


Swindon, United Kingdom
Swindon
United Kingdom


Re: Ceiling downlights
Reply #4 - Jun 15th, 2019, 9:30pm
 
Thanks guys Grin

Finding a replacement might be easy.  It was a pack of 8, and only 6 got fitted.  So somewhere in the shed there should be another 2.  Probably quicker to just replace all 6 though  Grin

I did try easing it off the ceiling with a couple of plastic pry bars, but it didn't feel like it was going to play.  Didn't know if I had missed something obvious.  I'll give it another go tomorrow
Back to top
 
Thank User For This Post WWW View members image gallery  
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8815


Total Thanks: 109
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: Ceiling downlights
Reply #5 - Aug 9th, 2019, 7:54pm
 
Some makes can make a mess if not carefully done.  JCC for one.  The heat from halogen lamps causes the can of the light to become hot, which then makes the plasterboard brittle.  The heat also damages the lamp holders.  They are a horrible design.  If you do pop any plaster around the hole, the lip of the fitting is too small to cover it.  Such a crap, rushed design when fire rated fittings first came out.

I would highly recommend removing them and fitting some Collingwood H2 Pro 700T, or 550T.  The 700 is equivalent to a 50watt halogen, and just 8watt.  The 550 closer to a 35watt.  They are excellent fittings.