Welcome, Guest. Please Login or Register
Welcome To Ask The Trades!
Apr 16th, 2024, 8:13am
Quote: If you can think of a random quote - Let us know!!


Page Index Toggle Pages: 1
Send Topic Print
Baxi Combi problem (Read 1266 times)
molegrip
Junior Member
**
Offline

Ask The Trades
Posts: 17


Total Thanks: 1
For This Post: 0



Baxi Combi problem
Dec 15th, 2019, 1:57pm
 
Hello all. Been babysitting an old Baxi105e for three years and it's not a disaster but a bit temperamental. Current niggle : first time in the day, the CH side only fires up if the Hot water is run at the tap first for a few minutes. On turning the hot tap off the CH smoothly takes over and continues to temperature. When the CH fails to fire up, the 'Low pressure / faulty pump' alert light comes one, though the pressure gauge shows just over 1 bar and the pump makes no noise and seems fine. Any ideas ? Thanks.

Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Baxi Combi problem
Reply #1 - Dec 16th, 2019, 9:45am
 
What is the boiler pressure first thing in the morning, if it's below 1.2bar it needs topping up

Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
Page Index Toggle Pages: 1