| Ask The Trades | |
|
https://www.askthetrades.co.uk/cgi-bin/yabb/YaBB.pl
DIY Forum >> Plumbing Questions >> decorative pipe covers https://www.askthetrades.co.uk/cgi-bin/yabb/YaBB.pl?num=1133646970 Message started by chocdrop on Dec 3rd, 2005, 9:56pm |
|
|
Title: decorative pipe covers Post by chocdrop on Dec 3rd, 2005, 9:56pm Anyone know where I can get some wrap around covers from (chrome ideally). I need to cover over a gas pipe that runs through a kitchen worktop and looks a bit ugly so thought I’d cover it up. The pipe is about 33mm wide |
|
Title: Re: decorative pipe covers Post by thescruff on Dec 4th, 2005, 12:10am wrote on Dec 3rd, 2005, 9:56pm:
Ok chopdrop seen you're other posts, now for some questions that require answers. http://i13.photobucket.com/albums/a259/allyourbitz/splashback/Picture006.jpg The pipes look like 1" steel, is one the incoming mains to the meter and the other the supply to the flat. where do the pipes enter or exit the flat. Is this a tenented flat or owner occupied, if the first is there a safety certificate. Looking at the pic several regs have been broken, cables have to be a set distance from the gas, not zip tied to it ;D Yes as I said you can box it in if the box is ventilated. |
|
Title: Re: decorative pipe covers Post by chocdrop on Dec 4th, 2005, 5:55pm owner occupied. The pipes are the incoming and and supply as you stated. It comes into the flat about 2 feet above what you can see in the photo and off to the left which is the external wall. I'll let the customer know about the cables. What is the distance they need to be from the pipe? |
|
Title: Re: decorative pipe covers Post by thescruff on Dec 4th, 2005, 7:10pm at least 150mm away from electrical meters and associated excess current controls or fuse boxes. at least 25mm away from electrical supply and distribution cables or other metallic services. where spacing requirements are impractical the pipe should be wrapped with pvc or an insulating material fitted between pipes. Plastic conduit or surface trucking would be ok. The pipes must be sleeved where they pass through the walls and sealed on the boxed in side. air vents to atmosphere must be fitted top and bottom, the cupboard would be fine for the bottom if you drill a few holes and then vent the space (cupboard) |
|
Title: Re: decorative pipe covers Post by graham555 on Dec 6th, 2005, 9:32pm Wickes have "coversnap" which comes in white and chrome 3ft lengths, B&Q i could only get white. |
|
Title: Re: decorative pipe covers Post by thescruff on Dec 7th, 2005, 12:05am wrote on Dec 6th, 2005, 9:32pm:
What for 1" steel pipes I doubt it very much :-/ |
|
Title: Re: decorative pipe covers Post by billythekid on Dec 8th, 2005, 12:50am how about running a saw down a bit of chromed 32mm pvc? Course I havent seen any longer than about a foot and a half! lol btk |
|
Title: Re: decorative pipe covers Post by grahamthebrickie on Dec 8th, 2005, 7:43pm For a 1" pipe you would use 2 pieces of coversnap overlapping each other!!! |
|
Title: Re: decorative pipe covers Post by billythekid on Dec 8th, 2005, 9:10pm or chrome spray paint :o btk |
|
Ask The Trades » Powered by YaBB 2.3! YaBB © 2000-2008. All Rights Reserved. |