Title: Had a British Gas guy round today! Post by kp1512 on Jan 30th, 2007, 7:27pm Well was time for a service of the boiler in the new place He cam round, did the service, etc etc But he also said that there was sludge in the system. He said there were these devices which you can put onto the COld Water feed coming in which would get rid of the sludge, and stop the banging noises and save the pump from more work. What is the best way to remove this build up of scale and hardwater deposits? KP |
|
Title: Re: Had a British Gas guy round today! Post by thescruff on Jan 30th, 2007, 8:15pm Best thing to fit on the heating return near the boiler is a "Magnaclean" about £85.00 but shop around. A quick search should give you loads of outlets for them. Hard water is a different part of the system and gadgets like the "Scalemaster" will help. |
|
Title: Re: Had a British Gas guy round today! Post by kp1512 on Mar 29th, 2007, 5:38pm scruff Will the Magnaclean sort out the sludge and oxide in the heat exchange in the boiler? thats also where Im getting a lot of noise.... Or, do you recommend a Powerflush?... KP |
|
Title: Re: Had a British Gas guy round today! Post by thescruff on Mar 30th, 2007, 10:00pm The Magnaclean will take the oxide out of the system before it gets to the heat exchanger. Whether it's too late for you is another story. Powerflush is ok if done properly, otherwise a waste of money. |
|
Title: Re: Had a British Gas guy round today! Post by The_Trician on Mar 30th, 2007, 10:35pm Hi Scruff, Are these things ok to be fitted to a pressurized combi system? TT |
|
Title: Re: Had a British Gas guy round today! Post by thescruff on Apr 1st, 2007, 12:56am Yes TT they can be fitted to any system. |
|
Title: Re: Had a British Gas guy round today! Post by kp1512 on Apr 1st, 2007, 5:35pm Scruff Im certain theres some in the HE as I can hear the curdling when the heating is on in the boiler......surely this gets pumped around? or as its heavy does it stay there? in which case WTF do I do? lol What are your thoughts in the Sentinal stuff? |
|
Title: Re: Had a British Gas guy round today! Post by thescruff on Apr 1st, 2007, 6:40pm If its in suspension and floating a around the system the Magnaclean will grab it. If however its stuck in the HX then a chemical flush is the only way out other than a new HX. Initially if the system is working then go for the Magnaclean and see what happens. |
|
Title: Re: Had a British Gas guy round today! Post by CWatters on Apr 18th, 2007, 6:46pm I've no idea how well the magnaclean works but read this report by the US Army. They tested the ability of three other devices to stop build up (not reducing existing build up) ... http://www.cecer.army.mil/techreports/Hock_MagneticDescalers/Hock_MagneticDescalers.pdf Quote:
|
|
Title: Re: Had a British Gas guy round today! Post by thescruff on Apr 18th, 2007, 10:29pm The Magnaclean is not a descaler, it attracts the magnatite and acts as a system filter to protect the heat exchanger |
|