DIY Forum >> Plumbing Questions >> Cold water feed getting hot https://www.askthetrades.co.uk/cgi-bin/yabb/YaBB.pl?num=1292759995 Message started by win41 on Dec 19th, 2010, 11:59am |
|
|
Title: Cold water feed getting hot Post by win41 on Dec 19th, 2010, 11:59am Hi, I have noticed that my cold water feed pipe get hot, in fact hot right up to ceiling, is this normal? I have a conventional gravity feed system Thanks It is the main cold feed from the expansion tank and is connected into the central heating pump |
|
Title: Re: Cold water feed getting hot Post by thescruff on Dec 19th, 2010, 2:07pm Need more information. If you mean the cold feed for the heating, it could be normal, but if you mean the cylinder cold feed, you have a back feed. |
|
Title: Re: Cold water feed getting hot Post by win41 on Dec 19th, 2010, 7:57pm Thanks for the reply, it is the main cold water feed from the expansion tank that comes into the top of the central heating pump . |
|
Title: Re: Cold water feed getting hot Post by thescruff on Dec 20th, 2010, 3:20pm Yes that would be normal in most cases, Posting a pic showing the pipe and pump layout would be good. It should go. Boiler > vent pipe > cold feed > pump > by-pass > MV. |
|
Title: Re: Cold water feed getting hot Post by greg on Dec 20th, 2010, 10:57pm It is a feed pipe, but also an expansion pipe so as Scruff said, quite normal |
|