| Ask The Trades | |
|
https://www.askthetrades.co.uk/cgi-bin/yabb/YaBB.pl
DIY Forum >> Plumbing Questions >> oil boilers - fitting a pipe stat https://www.askthetrades.co.uk/cgi-bin/yabb/YaBB.pl?num=1298310280 Message started by baffman on Feb 21st, 2011, 5:44pm |
|
|
Title: oil boilers - fitting a pipe stat Post by baffman on Feb 21st, 2011, 5:44pm Hi there During the recent spell of cold weather our boiler has been going on and off a lot of the time due to the cold temperatures. We have a frost stat that is fitted as the boiler is in the garage and this i believe has been controlling the boiler. If i was to fit a pipe stat on the return to the burner, im assuming this would reduce the amount of cycling on and off. I understand that it would still happen, just not as often. My question is how do i wire a pipe stat in? We have a y-plan system and the boiler is a thermecon option 40/60 thanks for any help cheers baff |
|
Title: Re: oil boilers - fitting a pipe stat Post by londonman on Feb 21st, 2011, 9:54pm I'm not an expert but it sounds to me as if the frost stat is doing what it is supposed to do! Otherwise your boiler will freeze up. |
|
Title: Re: oil boilers - fitting a pipe stat Post by thescruff on Feb 21st, 2011, 10:24pm Fit the pipe stat on the heating return. To wire it you just interrupt the the feed to the frost stat, so it's in line. |
|
Title: Re: oil boilers - fitting a pipe stat Post by baffman on Feb 22nd, 2011, 9:48am do i just wire it into the control box in the same place that the frost stat is wired into? tks baff |
|
Title: Re: oil boilers - fitting a pipe stat Post by thescruff on Feb 22nd, 2011, 11:36am Take the feed wire to the frost stat, and stick it in the com (pipe stat) then from the pipe stat to the frost stat. Simply put the pipe stat is just an inline switch to the frost stat. |
|
Title: Re: oil boilers - fitting a pipe stat Post by baffman on Feb 22nd, 2011, 2:33pm so i dont need to go near the wiring box? Which wire from the frost stat is it and where does this go on the pipe stat, and where which wire from the pipe stat goes to the frost stat and where do i put it in the frost stat? sorry for the silly question |
|