DIY Forum >> Plumbing Questions >> Ventilation requirments??
https://www.askthetrades.co.uk/cgi-bin/yabb/YaBB.pl?num=1303834628

Message started by WJOHNM on Apr 26th, 2011, 5:17pm

Title: Ventilation requirments??
Post by WJOHNM on Apr 26th, 2011, 5:17pm

Gas engineer at my house today.(i was at work)
After 1 and a half hours announces that the 'ventilation was undersized
High level 140 cm squared required'
Once this work is completed re schedule..
DO NOT USE BOILER!!!
There is a vent there 200X125 by a make of  'stadium'
2 floor vents and double doors are 50mm up from carpet.

advice on the high level vent please.
thanks in advance.

Title: Re: Ventilation requirments??
Post by TIMBA-WOLF on Apr 26th, 2011, 5:32pm

what boiler is it????

Title: Re: Ventilation requirments??
Post by WJOHNM on Apr 26th, 2011, 5:35pm

Its a Potterton Kingfisher 2.

Title: Re: Ventilation requirments??
Post by CWatters on Apr 26th, 2011, 6:06pm

Which size?

Perhaps see "COMBUSTION AIR AND VENTILATION REQUIREMENTS" in here....

http://www.partsarena.co.uk/baxi/System/DATA/Dx/DS1/installation/2547/I23-2547/I23-2547.htm

I'm NOT a gas fitter so wait for someone who is to reply.  


Quote:
b. The CF125 and CF150 may be installed in a purpose designed or modified compartment.

There should be two permanent air vents, one at low level and one at high level, both communicating either directly with outside air or indirectly with a room or internal space which is suitably ventilated (See a.). Each vent must have a minimum free area in accordance with the following table:




A vent 20 x 15 has an area of 250cm^2 less any grill. That appears to be a lot less than the 440 or 528cm^2 specified in the table for the high level vent.

Title: Re: Ventilation requirments??
Post by thescruff on Apr 28th, 2011, 1:16am

Ventilation requirements have been upgraded CW, the engineer would be near enough not to argue with..

Then again if the flag is anything to go on they have different regs to us.

Ask him what the requirements are and you can work it out, or buy a new boiler and save some money long term.

Title: Re: Ventilation requirments??
Post by WJOHNM on Apr 28th, 2011, 5:13pm

Thanks all,
I fitted a 9" x 9" vent giving 207cm squared.
More a bit miffed at turning the boiler off and leaving a sticker with do not use .
I did/do check to see if my boiler comes under the scrapage scheme but no,i.ll continue to have it regulary serviced.
cheers

Title: Re: Ventilation requirments??
Post by thescruff on Apr 28th, 2011, 11:52pm

The alternative, had you refused to let him turn it off, was to phone Transco and they would pop round and cap the supply.  ;D

Title: Re: Ventilation requirments??
Post by CWatters on Apr 29th, 2011, 11:09am

Gas Engineers can't fit vents?

Title: Re: Ventilation requirments??
Post by thescruff on Apr 29th, 2011, 2:25pm


CWatters wrote on Apr 29th, 2011, 11:09am:
Gas Engineers can't fit vents?


They can do anything if they have the inclination.

This is a typical BG post.

Title: Re: Ventilation requirments??
Post by WJOHNM on Apr 29th, 2011, 5:26pm


CWatters wrote on Apr 29th, 2011, 11:09am:
Gas Engineers can't fit vents?

Would the same of happened to a elderly lady/man??
After a phone call they would fit the vent required (12 minutes labour £71)
Ha Ha,I,ll have in by the morning. :P

Title: Re: Ventilation requirments??
Post by thescruff on Apr 30th, 2011, 3:43am

Hey BG love old, they are their main prey.  [smiley=headbang.gif]

Title: Re: Ventilation requirments??
Post by CWatters on Apr 30th, 2011, 6:54pm

What I want to know is this..

Presumably he had to open or remove the cupboard door to service the boiler. Couldn't he have just left the door off until someone put a vent in it?