DIY Forum >> Plumbing Questions >> Replace drain tap on Baxi 105e - is this how? https://www.askthetrades.co.uk/cgi-bin/yabb/YaBB.pl?num=1386103566 Message started by Jhiker on Dec 3rd, 2013, 8:46pm |
|
|
Title: Replace drain tap on Baxi 105e - is this how? Post by Jhiker on Dec 3rd, 2013, 8:46pm I need to replace the (white) drain tap on my Baxi 105e combi as it appears to be dripping. Do I just shut off the feed & return taps on the rear tap rail, drain via the white tap into a bucket, replace the drain tap, turn on the feed & return taps and re-pressurise with the filling loop? Have I missed anything. Many thanks! |
|
Title: Re: Replace drain tap on Baxi 105e - is this how? Post by thescruff on Dec 3rd, 2013, 10:34pm Make sure it isn't dripping down from elsewhere, and take your time |
|
Title: Re: Replace drain tap on Baxi 105e - is this how? Post by Jhiker on Dec 4th, 2013, 9:24am thescruff wrote on Dec 3rd, 2013, 10:34pm:
Will do. But I have the procedure right - right? Thaqnks ;) |
|
Title: Re: Replace drain tap on Baxi 105e - is this how? Post by thescruff on Dec 4th, 2013, 2:03pm Never tried it on the Baxi but all sounds about right. Just one thing looking at the MI, I would also turn the cold mains to the boiler off. And avoid any water getting on/into the electrics |
|