Title: 43mm or 40mm waste?
Post by Dusty on Aug 12th, 2004, 7:14pm

:D :D :D :D :D
Just about to fit a new kitchen ;)
The new sink comes with 40mm waste pipes, yet the local trade suppliers only stock 43mm and the DIY store 40mm. ???
As I also need to install new waste for the WM & DW should I use 40 or 43 8)
Will one supersede the other in time :-/

Thanks :)
Dusty :D

Title: Re: 43mm or 40mm waste?
Post by thescruff on Aug 13th, 2004, 4:12pm

Until someone shows me otherwise, they don't make 43mm.

11/2" is classed as 40mm, 2" is 50mm.

Some confusing exists because some makes measure inside and some outside, and some vary slightly in size, for example the push fit stuff is smaller than the solvent weld.

For your kitchen depending on the length of pipe run 40mm should be ok although I prefer 50mm and reduce the branches top each appliance.

scruff

Title: Re: 43mm or 40mm waste?
Post by Dusty on Aug 14th, 2004, 1:19am

Thanks, that must be it.
One is solvent & the other is push fit.
I'm sure the waste I need to connect it all to is solvent (43) & as the new sink is push fit (40) how can I connect the two different sized pipes?
Thanks
Dusty

Title: Re: 43mm or 40mm waste?
Post by HandyMac on Aug 14th, 2004, 5:41am

A plastic compression fitting usually takes care of this problem in my experience.

Andrew

Title: Re: 43mm or 40mm waste?
Post by thescruff on Aug 14th, 2004, 7:56am


wrote on Aug 14th, 2004, 1:19am:
Thanks, that must be it.
One is solvent & the other is push fit.
I'm sure the waste I need to connect it all to is solvent (43) & as the new sink is push fit (40) how can I connect the two different sized pipes?
Thanks
Dusty


You didn't read my first reply, They don't make 43MM or at least not in my teritory.

Solvent is 40mm push fit is slightly smaller.

A compression fitting will in most cases convert the various pipes.

scruff

Title: Re: 43mm or 40mm waste?
Post by Dusty on Aug 14th, 2004, 1:12pm

I’m still confused, yes the pipes say 40mm on the side, however I have 2 sections in front of me and a pair of digital venire callipers
One is made by Marley BS 5255 – OD = 43.01mm  ID = 38.59mm (came from the Plum Center)
The other from Homebase – OD = 40.86mm  ID = 35.87mm.
In addition to this, if you buy a 90º elbow from the Plum Center you will see it has 43 (1 ½) on it.
Although they may call the tubing 40, they clearly do make a 43mm size.

Title: Re: 43mm or 40mm waste?
Post by thescruff on Aug 14th, 2004, 1:57pm

Plumb brand, Terrian, Marley and a few other solvent weld are all compatable, the odd ones out are Rimway and Bartol.

To confuse the issue the pipe is an id size ie, 32mm & 39mm and are sized to fit the old 11/4 and 11/2 pipes.

McApine traps for example are sold as 39mm for 11/2, Terrain are .15 and .125 11/2/and 11/4 repectively.

I have noticed on a new bag of plumb bends that they are marked ABS 40mm, on the fittings in the bag 43mm (11/2) they are however listed as 32 and 40 and sold as such.

scruff

Title: Re: 43mm or 40mm waste?
Post by thescruff on Aug 15th, 2004, 7:55pm

below is a link to the Terrain site, which may be handy, download the pdf for soil and wastes.

scruff

http://www.geberit.co.uk/gb/Webgb.nsf/pages/abou-1-3


Title: Re: 43mm or 40mm waste?
Post by PEDANTICVINDICTIVEMAN on Aug 15th, 2004, 8:14pm

All you need to do is this, either buy a pushfit universal coupling, or a universal compression coupling, or if using solvent weld stuff, heat the pipe or smalller fitting up with your blowlamp waft the flame over quickly until it is pliable  being careful not to burn it, then either open up the smaller fitting by forcing in the pipe or open up the solvent pipe by forcing anothe peice of pipe into it, then  solvent together. ;)
keep the blowlamp away from the tin of solvent, whhoooooooofffffff.

Title: Re: 43mm or 40mm waste?
Post by thescruff on Aug 15th, 2004, 8:22pm

You made that sounds soooooooooo easy PVCman  :-X

Don't try it with push fit.

scruff

Title: Re: 43mm or 40mm waste?
Post by LRon on Dec 24th, 2010, 2:48pm


thescruff wrote on Aug 13th, 2004, 4:12pm:
Until someone shows me otherwise, they don't make 43mm.

11/2" is classed as 40mm, 2" is 50mm.

Some confusing exists because some makes measure inside and some outside, and some vary slightly in size, for example the push fit stuff is smaller than the solvent weld.

For your kitchen depending on the length of pipe run 40mm should be ok although I prefer 50mm and reduce the branches top each appliance.

scruff
...hi,here is some 43mm.
[gallery]LRon99/1293201903.jpg[/gallery]

Title: Re: 43mm or 40mm waste?
Post by thescruff on Dec 24th, 2010, 9:21pm

The post is over 6 years old LRon.  ;D

Title: Re: 43mm or 40mm waste?
Post by jjamjar on Jan 9th, 2012, 4:00pm

I've just come up against the same problem.
@ thescruff: it might have been 6 years ago but your advice to the OP was a bit lacking: he measured his pipes with a digtal calliper and gave the BS info which you ignored. In 2001 a new standard came in for small pipes replacing BS5255 with BS EN 1451-1. The fact is that the actual OD size [as opposed to the nominal size] has changed from 43mm to about 41.5. Osma have kept all the same part numbers but the new are not compatible with the old except via a universal adaptor.

Title: Re: 43mm or 40mm waste?
Post by thescruff on Jan 9th, 2012, 4:35pm

Always up for an intelligent and educational post jamjar  ;D

Are you saying there's a standard now whereas all plastic pipe is the same size now.

And if that is the case why haven't they told all the manufacturers.  ::)

Title: Re: 43mm or 40mm waste?
Post by TIMBA-WOLF on Jan 9th, 2012, 6:01pm

And my 2012 OSMA book does not list an ADAPTER!!!

strange that,