Ask The Trades | |
https://www.askthetrades.co.uk/cgi-bin/yabb/YaBB.pl
DIY Forum >> Electrical Questions >> Hand dryer Disable toilet https://www.askthetrades.co.uk/cgi-bin/yabb/YaBB.pl?num=1096404862 Message started by supra59 on Sep 28th, 2004, 9:54pm |
Title: Hand dryer Disable toilet Post by supra59 on Sep 28th, 2004, 9:54pm Hello all Does anybody no the correct height for a hand dryer in a disable toilet in a comercial property and clarify light swich height is 1100 mm from the floor cheer lads and girls if any |
Title: Re: Hand dryer Disable toilet Post by L.Spark on Sep 29th, 2004, 2:35pm Hey Again Supra With ref to suitable heights, I have found the following for you Hand dryer should be at a height of 800mm\1000mm (to bottom of unit) Light switches can be either a large push button or by a pull cord. Pull cords should be set between 900mm and 1100mm above floor level and fitted with a 50mm diameter bangle visually contrasting with its background and distinguishable visually from any emergency assistance pull cord. |
Title: Re: Hand dryer Disable toilet Post by supra59 on Sep 29th, 2004, 5:51pm hi L Spark that will do me nicely thanks for the quick responce i wil get that put in tomorrow. thanks again supra |
Title: Re: Hand dryer Disable toilet Post by L.Spark on Sep 29th, 2004, 7:54pm Anytime :) |