DIY Forum >> Plumbing Questions >> Noisy valve
https://www.askthetrades.co.uk/cgi-bin/yabb/YaBB.pl?num=1103624615

Message started by Geddy on Dec 21st, 2004, 10:23am

Title: Noisy valve
Post by Geddy on Dec 21st, 2004, 10:23am

I have a problem with a noisy float valve in our high level cistern.

The cistern fills very quickly and efficiently but as it shuts off there is severe vibration noise coming from the float valve. I know we live in a high pressure area (5 bar) so turned down the isolating value but the problem persists.

Should I turn down the internal stop cock or is there another remedy?. I don't really want the performance of the shower and other fittings to suffer.

Title: Re: Noisy valve
Post by billythekid on Dec 21st, 2004, 5:10pm

has it always done that or has it recently happened? If recent try changing the float valve washer, if always may need pipes clipping somewhere. normally water hammer/noisy valves are due to wear on the washers although bad installation can also be a factor.

Title: Re: Noisy valve
Post by Geddy on Dec 21st, 2004, 5:12pm

Thanks

The installation is new so it sounds like additional clipping is required

Title: Re: Noisy valve
Post by Plumber on Dec 21st, 2004, 9:18pm

Try fitting an equalibrium ballvalve