Shop door bell

customer walks in opens door magnetic contact makes doorbell dings, door closes door contact breaks doorbell dongs.

but sometimes contact not breaking. to much current for an alar contact?

Title: Re: SHOP DOORBELL
Post by Lectrician on Jul 24th, 2015, 3:41pm

Too much current IMO.  Replace contact, use a relay.

Title: Re: SHOP DOORBELL
Post by scotspark on Jul 24th, 2015, 3:46pm

that's what I guessed  :-/

im away tonight so will need to wait till im back  :-/

Title: Re: SHOP DOORBELL
Post by baz on Jul 25th, 2015, 8:30pm

Most of those alarm  switch contacts are rated at 0.5amp resistive.
Ding dong bell transformers are rated at 1amp and need most of that (if you've tried adding a second bell you'll know what happens). Also the bell will be a tad inductive.

Something like this, would hack it
https://www.tlc-direct.co.uk/Products/FM143W.html

Title: Re: SHOP DOORBELL
Post by scotspark on Jul 30th, 2015, 12:43pm

Unfortunately die squibs both ways