electric underfloor heating (Read 5346 times)
harryw
GDPR opt-out









electric underfloor heating
Jul 25th, 2010, 3:00pm
 
I have a 24m X 0.5m electric underfloor heating mat(ThermoLam) and I need to reduce the length by several meters. How should the ends of the heating element wires be joined. A qualified electrician will be testing and doing the final connection.
Thanks for your help. Harryw
Back to top
 
 
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: electric underfloor heating
Reply #1 - Jul 25th, 2010, 5:57pm
 
You can't cut the cable. See page 10..

http://www.ambient-elec.co.uk/Files/thermolam-foil-heater-instructions-ambient-e...

Quote:
ThermoLAM MATS MUST NEVER BE CUT OR TRIMMED TO FIT INTO A SPACE THAT IS TOO SMALL!


I suspect the reason for this is that the length determins the resistance. Cutting it shorter would increase the power dissipated - possibly overheating the mat and the floor.

You can cut the foil (only the foil, not the cable) so that the mat can folded into a different shape. See page 9.  If that doesn't help take it back and get one the right size.
Back to top
« Last Edit: Jul 25th, 2010, 5:59pm by CWatters »  
Thank User For This Post View members image gallery  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: electric underfloor heating
Reply #2 - Jul 25th, 2010, 6:20pm
 
I note that they don't list a 24 meter x 0,5 meter mat in the instructions. Are you sure it's not a 20m long mat?

More on the reason why you can't cut it down... Suppose you have a 20m mat athen the resistance is 38 ohms. If you were to (incorrectly) cut say 5 meters off the end the resistance would reduce to 15/20 x 38 = 28.5 Ohms. The power would go up from around 1400W to 1900W. However because the area is also reduced from 10sqm to 7.5sqm the power density goes up from 140W/m^2 to 253W/m^2. That's an 80% increase. The mat isn't designned for that and the might overheat itself or the floor covering.

Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
harryw
Re: electric underfloor heating
Reply #3 - Jul 25th, 2010, 7:58pm
 
Thanks for your help. I was afraid that would be the answer, but I wasn't sure my logic was right.  By the way cwatters we share a surname HW
Back to top
 
Thank User For This Post  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: electric underfloor heating
Reply #4 - Jul 27th, 2010, 12:12am
 
There are a few of us about. We've traced our Watters line back to 1810 ish. They were in India for about 100 years.
Back to top
 