can anyone help please ? (Read 2175 times)
markw
GDPR opt-out









can anyone help please ?
Oct 26th, 2006, 4:27pm
 
have an indirect hw/ch system (with potterton suprima boiler) that intermittantly trips the main rcd when using the programmer to turn the heating on at the set times. The only way i can consistantly turn on the hw or ch without it tripping is when i manually start up the hot water by turning on the power with the cylinder stat on its lowest setting and then turning the stat temp setting up. This is the way to tuern the CH on as well. I presume this rules out any wiring problem and i have already replaced the programmer. One CH engineer and multimeter has already given up on this one. Appreciate any help
Back to top
 
 
IP Logged
 
scotspark
Trade Member
*****
Offline

mmmmm it's gonna cost
you!!
Posts: 3074


Total Thanks: 10
For This Post: 0


scotland, Scotland
scotland
Scotland

Gender: male

Trade: Electrician



Re: can anyone help please ?
Reply #1 - Oct 26th, 2006, 5:01pm
 
only thing i have come across before has been a motorised valve letting water into its eletrics.


doesn't sound the case here tho.

Back to top
 

brown to red and blue to f****&&&&ommited!!!!!!!!!!!!!!!!!!!!!!!!!!!
Thank User For This Post View members image gallery  
IP Logged
 
chtechie
Re: can anyone help please ?
Reply #2 - Oct 26th, 2006, 6:17pm
 
Had a couple of installations where the valve is directly below the pump and those isolator valves with a slot have been used - these valves leak and make the valve wet - RCD trips.
Back to top
 
Thank User For This Post  