Oh no not another heating problem!! (Read 2147 times)
ColG
GDPR opt-out









Oh no not another heating problem!!
Nov 16th, 2006, 11:45pm
 
Hello Chaps, haven't been in here for ages.

Anyways I have a problem.  Heating wasn't working after the summer recess, could get HW but this to eventually died.  Boiler fired up, pipes got hot as far as pump, boiler then cutout = me thinks must be blockage as had had problem before.

So I decided to do a proper job and powerflush the system, install new rads and generally update the system.

System works a treat now - tooooo fekking hot according to the misses however, I have a couple of issues which I hope you can help me resolve.

Firstly, the boiler is as noisy as buggery clanks, cracks, bangs and all the other words to describe a noisy boiler.

Secondly, water is peeing out the header overflow and the cold feed to the system is very hot.

My thought is that there may well still be air in the system.  I did cut out and replace a section of pipe that contained two Tees and an elbow in close proximity which linked the expansion pipe, feed pipe to the boiler.

I've thought about putting automatic air valves in but thought I run it past the experts first.

Thanks awfully for your help.

Cheers
Col



Back to top
 
 
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Oh no not another heating problem!!
Reply #1 - Nov 17th, 2006, 12:41am
 
Oh Dear  Shocked

I just wish you guys realised how bl00dy dangerous it is to play with things you don't understand.

Quote:
 I did cut out and replace a section of pipe that contained two Tees and an elbow in close proximity which linked the expansion pipe, feed pipe to the boiler.


perhaps a pic or drawing before it blows up
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: Oh no not another heating problem!!
Reply #2 - Nov 17th, 2006, 7:58am
 
He did say he replaced the pipe. Just hope he replaced it the same way!