Best position for MAGNACLEAN (Read 2956 times)
nyck
GDPR opt-out









Best position for MAGNACLEAN
Jan 14th, 2007, 2:47pm
 
I just bought a Magnaclean and need your help for the best position .Is it OK to fit it horizontal rather than vertical as it would be much easier to fit and service.I posted below a link to some photos where i want to fit it and the other options but will be a bit tight and awkward to get at.
Also in photo 2 what is the item i have circled in blue ,is it a filter would i remove it when i fit the Magnaclean

thanks nyck

http://uk.pg.photos.yahoo.com/ph/nyckuk/detail?.dir=bf97scd&.dnm=1f37scd.jpg&.sr...
Back to top
 
 
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Best position for MAGNACLEAN
Reply #1 - Jan 14th, 2007, 5:54pm
 
No they are best mounted vertically in the return pipe.

Drop an elbow of the pipe to the lower connection.

Looking at the pic, if you cut the pipe where the red line is, and take it into the magnaclean, the return connections can connect anywhere in the pipe back to the boiler.

The item circled is a filter installed the wrong way up Shocked
Back to top
« Last Edit: Jan 14th, 2007, 5:59pm by thescruff »  
Thank User For This Post View members image gallery  
IP Logged
 
nyck
Re: Best position for MAGNACLEAN
Reply #2 - Jan 15th, 2007, 8:13am
 
Just had a look at the box it came in and it show you various valve postions that arn't shown in the installation instructions
so if you look here at both photos
http://uk.pg.photos.yahoo.com/ph/nyckuk/detail?.dir=b162scd&.dnm=8292scd.jpg&.sr...

this is my new plan ,i can just about get the lid off and out if fit like this.

Do i remove that other filter or doesnt it matter either way

thanks nyck
Back to top
 
Thank User For This Post  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Best position for MAGNACLEAN
Reply #3 - Jan 15th, 2007, 6:21pm
 
The other filter is doing nothing anyway so take it out, although that is not completely true, what it will do is collect any crud and block the pipe.

You can then lower the return pipe a few inches to give yourself more room.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
Page Index Toggle Pages: 1