Mains Water Stop Cock (Read 6569 times)
XDR5
GDPR opt-out









Mains Water Stop Cock
Jun 11th, 2007, 4:41pm
 
The main stop cock on the water supply into my house has decided to fail and can now only be turned partially off.  (It is one of the tap-type with 15mm compression fittings at either end)

This stop cock was fitted by me quite some years ago when the previous one failed and has been turned off/on several times each year since in order to keep it operational.

I know of several friends who have had similar problems resulting in the stop cock having to be replaced.

My questions are these:
Does the stop cock have to be the tap-type or could I use some other type of fitting - a lever-operated ball valve, a service valve or a gate valve to name a few?
Would any of these be less prone to failing?
Are there any regulations which come into play here?

I do not need to reduce the mains pressure as in normal service the stop cock is fully open.  The water in my area is quite hard but build up of scale is not a problem on the mains supply.

Any help/advice much appreciated.
Back to top
 
 
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Mains Water Stop Cock
Reply #1 - Jun 11th, 2007, 6:40pm
 
You could fit a fullflow lever ball valve, provided you also fitted a double check valve and draincock.

Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
XDR5
Re: Mains Water Stop Cock
Reply #2 - Jun 12th, 2007, 12:34am
 
Thanks for the reply.

My current installation (house built early 70's) does not have a check valve - do I have to install one now if I replace the existing stop cock ??

I've also got a "Water Switch" which I am intending to install for use when I want to shut off the water supply before going away for holidays (the stop cock is behind a panel which is screwed to the wall).

Would the sequence of fittings be:
Incoming main
Stop Cock or Ball Valve
Water Switch
Double Check Valve
Plumbing to rest of house

Cheers.
Back to top
 
Thank User For This Post  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Mains Water Stop Cock
Reply #3 - Jun 12th, 2007, 6:55pm
 
You leave the old stopcock in place, then add the other bits above it.

I think you will find the water switch requires an isolation valve for servicing, but may already have an in built check valve.

Don't forget the draincocks.