Mar 1st, 2008, 3:22pm
 
I went to a customers house the other day to fix a rad leak, carried out the repair and topped up the boiler then fired it up ran for while then cut out. When I spoke to idealtech they said it was an air prob and to just keep firing the boiler,no good. Spoke again to ideal and they suggested removing the div valve head to help get rid of the air,no good. The third engineer at ideal suggested removing the pump head to ensure the impeller was still attached to the spindle and it wasn't, put a new pump on and bingo but my question is,why did the boiler not cut out at 0.5 bar as usual to prevent dry firing and does this indicate another component faliure.
Back to top
 
 
IP Logged
 
watty
GDPR opt-out









Re: IDEAL ISAR 24HE
Reply #1 - Mar 1st, 2008, 11:51pm
 
is nobody interested in this horrible boiler. come on give us a clue Smiley
Back to top
 
 
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: IDEAL ISAR 24HE
Reply #2 - Mar 2nd, 2008, 12:24am
 
Perhaps the dry firing thermistor is duff, or the gauge is blocked and you have more pressure than is shown,

What is the low pressure on these or have I got to get the book out again  Roll Eyes

Check resistance using a suitable multimeter
connected across the dry fire thermistor’s
terminal pins
At 25 oC expect 9,700 - 10,300 Ohms
At 60 oC expect 2,400 - 2,600 Ohms
At 85 oC expect 1,000 - 1,100 Ohms
Back to top
« Last Edit: Mar 2nd, 2008, 12:31am by thescruff »  
Thank User For This Post View members image gallery  
IP Logged
 
lovejoy
Re: IDEAL ISAR 24HE
Reply #3 - Mar 18th, 2008, 2:21pm
 
the gauge on a isar is fitted to the pipe wok and not a internal 1 i have had probblems with this guage on a number of occasions cheap nasty boiler and guage Undecided
Back to top
 
Thank User For This Post  
IP Logged
 
watty
Re: IDEAL ISAR 24HE
Reply #4 - Apr 10th, 2008, 7:37pm
 
thanks for the help.I think ill just leave it at that