Downlighters and fire protection
Mar 4th, 2009, 7:09pm
 
At the recent inspection by Building Control, the BCO wanted me to retro-fit intumescent stuff or other fire protection on the downlighters.  Now I seem to remember researching this at the time and thought that provided any inflammable material such as Kingspan was above a certain height above the luminaire then one did not require any form of fire protection.  

Can anyone shed any light, please?  Happy to provide further information.
Back to top
 

Would all Third Party Apologists kindly mind their own business .....
Thank User For This Post View members image gallery  
IP Logged
 
Zambezi
Re: Downlighters and fire protection
Reply #1 - Mar 4th, 2009, 10:37pm
 
My understanding is that you need to provide fire hoods or fire rated fittings when there are habitable rooms above the fittings. It is mainly to stop the spread of fire. If a fire starts in the living room the intumescent material in the light fitting/hood expands to close off the hole between upstairs and downstairs.

As standard I fit fire rated downlights like...
http://www.screwfix.com/prods/38373/Lighting-Lamps/Internal-Lighting/Fire-Rated-... it is much easier than trying to fit those silly floppy fire hoods that move and never sit properly.
Back to top
« Last Edit: Mar 4th, 2009, 10:42pm by zambezi »  
Thank User For This Post  
IP Logged
 
Goodsparks
Re: Downlighters and fire protection
Reply #2 - Mar 5th, 2009, 1:17am
 
Fire hoods are only generally required where a penetration has been made in a ceiling / wall / floor that is designed to provide fire integrity. This will vary from place to place. They will almost always be required where the ceiling / floor seperates two dwellings (flats maisonettes) (also to provide sound insulation (cant remember which building reg. that is)). Think along the lines of the stupid wind-up door closers the BCO insists you fit to provide integrity to the staircase when you convert the loft. Approved Doc. B will give guidance as to the places that need fire seperation for new builds / alterations, thats where the hoods / downlights will be required.

Back to top
 
Thank User For This Post  
IP Logged
 
londonman
Trade Member
*****
Offline

I love YaBB 1G - SP1!

Posts: 1697


Total Thanks: 13
For This Post: 0


Malvern, United Kingdom
Malvern
United Kingdom


Trade: Cabinet Maker

Re: Downlighters and fire protection
Reply #3 - Mar 5th, 2009, 7:50am
 
Thanks guys for the confirmation.


The downlighters he complained about were in a single story extension out the back.  So nothing habitable above.  He tried it on before with the casement windows - saying they should be hinged at the top so the whole window would swing upwards in the case of fire.  Told him that only applied to new builds and he backed down.

So telephone call today, I think.  If he gets stubborn then that's a great link, Z.
Back to top
 

Would all Third Party Apologists kindly mind their own business .....
Thank User For This Post View members image gallery  
IP Logged
 
Zambezi
Re: Downlighters and fire protection
Reply #4 - Mar 5th, 2009, 7:58am
 
Is he complaining about the spots in the conservatory/extension thing out the back? If so, then he has been beaten with the silly stick a few too many times! I guess if it makes him happy and you get your completion certificate then just change the fittings (a waste of time and money but for the sake of peace and your completion cert). You can buy packs of those fittings, I think 10 in a pack and they work out quite a bit cheaper.
Back to top
 
Thank User For This Post  
IP Logged
 
Lectrician
Administrator
Trade Member
Author
*****
Offline

Ask The Trades
Posts: 8815


Total Thanks: 109
For This Post: 0


Braunton, North Devon, United Kingdom
Braunton, North Devon
United Kingdom

Gender: male

Trade: Electrician



Re: Downlighters and fire protection
Reply #5 - Mar 5th, 2009, 8:12am
 
We fit the JCC fire rated ones, we pay £4.95 for them including a lamp.  This is the ELV version, but I am sure the GU10 version is the same sort of money.
Back to top
 

Need to post a picture? Click HERE for info!
Thank User For This Post WWW View members image gallery  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: Downlighters and fire protection
Reply #6 - Mar 5th, 2009, 8:39am
 
That's a good price.  TLC also have a range of fire rated but more like £6-£7.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
londonman
Trade Member
*****
Offline

I love YaBB 1G - SP1!

Posts: 1697


Total Thanks: 13
For This Post: 0


Malvern, United Kingdom
Malvern
United Kingdom


Trade: Cabinet Maker

Re: Downlighters and fire protection
Reply #7 - Mar 5th, 2009, 6:49pm
 
Well, as it happened the Aurora trade bus was parked outside my local distributor and I popped in for a chat.  The sales guy agreed 100% with what you guys have been saying (not that I ever doubted you!).

So armed with that I rang Building Control to see if I could speak to the BCO but he was on leave. I spoke (politely) to one of his colleagues who agreed with all that's gone before.  No need for them!!
Back to top
 

Would all Third Party Apologists kindly mind their own business .....
Thank User For This Post View members image gallery  
IP Logged
 
Page Index Toggle Pages: 1
Send Topic Print