Quote:My question is where would the SWA be run into the house? would it be off a fused spur from the CCU?
any help would be appreciated thanks
You could run it straight into your main consumer unit protected by an existing RCD or by installing an RCBO, a 20a rated MCB/RCBO respectively will be fine if your using equipment that isnt heavy in using current.
You could run it into an adaptable box external to your property, this adaptable box would have a supply from the main consumer unit using Twin & Earth cable.
You need to make sure the protective bonding conductors have been installed to the water and gas services, if they apply, before work commences.
Whats your earthing arrangement, TNS, TN-C-S, TT?
What is your shed made of? Does it have any metallic services in it i.e, water pipe?
You need to make sure your installation can handle the additional load as well.