Wiring in anticipation of socket move (Read 6677 times)
UnDIYenthusiast
GDPR opt-out









Wiring in anticipation of socket move
Oct 30th, 2009, 3:13pm
 
Hi,
Quick question about safe zones for wiring; I want to move a couple of sockets, but it seems from doing a bit of research that I can't run the cable behind the skirting as I had originally planned, which causes a few issues as we're getting the room replastered on Monday! I plan to put the new sockets at a height of about 12inches above the floor - the same height the 'feeder' socket is, so am I right in thinking that the wire needs to run around the room along a line this height? And if so, can I chisel out the run, put in coduit and 2.5mm cable before we get the walls plastered, and then fit the sockets after I've had an electrician look at it?
Any advice would be appreciated, I'm on a pretty tight schedule, so need to know if any of this is even feasible!
Thanks
Back to top
 
 
IP Logged
 
sparky415
Trade Member
*****
Offline

Its more complicated than
I first thought
Posts: 679


Total Thanks: 0
For This Post: 0


Gender: male

Trade: Electrician



Re: Wiring in anticipation of socket move
Reply #1 - Oct 30th, 2009, 6:38pm
 
Yes you can
How many sockets? It would be best to extend the ring.

   
Back to top
« Last Edit: Nov 3rd, 2009, 2:59pm by Lectrician »  
Thank User For This Post View members image gallery  
IP Logged
 
UnDIYenthusiast
Re: Wiring in anticipation of socket move
Reply #2 - Oct 30th, 2009, 7:05pm
 
There are three sockets in the room, two doubles next to each other where there used to be a gap in the fitted wardrobe, and one on the wall opposite. Of the two together I'm guessing one has been taken off the first, and as they're close by it should be relatively simple to take the wiring back to the first socket and replace with a longer piece... but haven't had chance to check, and we all know things are never simple! The other socket I think I'll blank off and take a spur round to the adjoining wall. What's the protocol with taking a wire round an internal corner? Just the same as a flat wall?

And lastly, am I right to think that if I were to take a cable out of a safe zone it would have to be adequately protected with some form of metal cladding?

Thanks, just trying to save costs as much as possible without sacrificing safety, so the more manual labour i can do myself the better.
Back to top
 
Thank User For This Post  
IP Logged
 
sparky415
Trade Member
*****
Offline

Its more complicated than
I first thought
Posts: 679


Total Thanks: 0
For This Post: 0


Gender: male

Trade: Electrician



Re: Wiring in anticipation of socket move
Reply #3 - Oct 31st, 2009, 5:10pm
 
Yes as you can see in the above diagram the safe zones join via the corner zone,

Its best to use the safe zones!
but if you can't you need to protect the cable,
an earthed bit of metal condiut is probably easiest tho there are other ways.