Hi all.
   I have a Potterton Performer 28 Combi boiler fitted in the kitchen. Over the past week i (and the missus!) have noticed a gradual drop in temperature of the upstairs hot tap water. It's now at the point of being luke warm. All radiators and other taps are fine throughout the house! Any ideas?? Huh
Back to top
 
 
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: 1st. Floor hot water is cold?
Reply #1 - Jan 21st, 2010, 7:16pm
 
Could the pressure be higher, try opening the tap less than usual.

Are they mixer taps that are maybe stopping the hot.

Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: 1st. Floor hot water is cold?
Reply #2 - Jan 22nd, 2010, 7:59am
 
Faulty shower mixer? eg letting cold through to the hot pipe and around to the tap?
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
jaggiethistle
Re: 1st. Floor hot water is cold?
Reply #3 - Jan 22nd, 2010, 12:43pm
 
Thanx for the reply folks!
 My water pressure is sitting at a constant 2.0 Bar when the heating is on. Is this ok?
 I do have mixer taps fitted to the bath and h/w basin. But is it likely that both of these would pick up a fault at the same time? and can you service them?
 
 I also have a mains fed mixer shower. I've isolated the cold supply this morning to the shower and turned the lever to full hot and it's still luke warm with just a moments rise in temp before settling back down to cold(ish) Huh
Back to top
 
Thank User For This Post  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: 1st. Floor hot water is cold?
Reply #4 - Jan 23rd, 2010, 12:20pm
 
The gauge on the boiler is system pressure and not the mains pressure, and 2bar when hot is ok.

Try turn the cold to the bath off and running the hot, at the same time measure the flow rate into a bucket, it should be 10-12Ltrs/m
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: 1st. Floor hot water is cold?
Reply #5 - Jan 25th, 2010, 10:25am
 
When you turn on the problem tap does the combi fire up normally or do anything different to what it does when running a working tap ?