Question on hooking up my new oil boiler (Read 5830 times)
pryantcc
GDPR opt-out









Question on hooking up my new oil boiler
May 24th, 2010, 2:21pm
 
Hi Everyone,
I'm about to hook up my new oil boiler. It has 4 outlets, one on each side at the top and one on each side at the bottom.

I realize return should go to the bottom and flow to the top, but I am wondering if there is any benefit to connecting flow and return to opposite sides of the boiler so that the water is drawn across it as well as upwards through it.

I’d be interested to hear any views or theory on the subject.

Thanks,
Paul.
Back to top
 
 
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: Question on hooking up my new oil boiler
Reply #1 - May 24th, 2010, 5:49pm
 
On our Grant oil boiler I believe there was one flow pipe fitted with an elbow that could be rotated so it exits the boiler on the left or the right. eg it makes no difference which side as it's the same pipe where it matters. I've no idea about other makes, have a look in the back of the boiler.

You will be getting a professional to commission it for you won't you.
Back to top
« Last Edit: May 24th, 2010, 5:49pm by CWatters »  
Thank User For This Post View members image gallery  
IP Logged
 
pryantcc
Re: Question on hooking up my new oil boiler
Reply #2 - May 24th, 2010, 9:35pm
 
CWatters wrote on May 24th, 2010, 5:49pm:
On our Grant oil boiler I believe there was one flow pipe fitted with an elbow that could be rotated so it exits the boiler on the left or the right. eg it makes no difference which side as it's the same pipe where it matters. I've no idea about other makes, have a look in the back of the boiler.

You will be getting a professional to commission it for you won't you.


I realise I'm opening myself to a barrage here, but no, I was going to commission it myself! The instruction manual is pretty thorough. The factory say they have pre-set the oil pump pressure (I'd check it but I don't have a guage) & all I have to to is to adjust the air flow until the CO2 levels are as per their spec. The air flow is just one screw, twiddle it until I have 11.5% CO2.

Please feel free to fill me in if I'm being naieve (spelling?)
Back to top
 
Thank User For This Post  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Question on hooking up my new oil boiler
Reply #3 - May 25th, 2010, 12:16am
 
Whilst you're reading the book it will tell you the configuration for the pipes.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
CWatters
Super Member
*****
Offline

"Daddy fick it" says James

Posts: 5150


Total Thanks: 58
For This Post: 0


Gender: male

Re: Question on hooking up my new oil boiler
Reply #4 - May 25th, 2010, 1:45am
 
Aren't new boiler installs 'Notifiable Works' under building regulations?  eg Aren't you meant to use an OFTEC approved bod or make a BCA?
Back to top
« Last Edit: May 25th, 2010, 1:48am by CWatters »  
Thank User For This Post View members image gallery  
IP Logged
 
pryantcc
Re: Question on hooking up my new oil boiler
Reply #5 - May 25th, 2010, 9:53am
 
CWatters wrote on May 25th, 2010, 1:45am:
Aren't new boiler installs 'Notifiable Works' under building regulations?  eg Aren't you meant to use an OFTEC approved bod or make a BCA?


I'm not in the UK, I'm in Ireland. Not sure if I need to notify anyone here, I'll do some googling though as I hadn't thought of that, thanks!!

The manual simply says to block 2 of the boiler outlets, it doesn't specify which two! Smiley
Back to top
 
Thank User For This Post  
IP Logged
 
thescruff
Global Moderator
Trade Member
Author
*****
Offline

Who said plumbing was
easy.
Posts: 6037


Total Thanks: 147
For This Post: 0


Gender: male

Trade: Plumber



Re: Question on hooking up my new oil boiler
Reply #6 - May 26th, 2010, 1:26am
 
A cross flow top one side bottom the other is best, is they don't specify an order.
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 
pryantcc
Re: Question on hooking up my new oil boiler
Reply #7 - May 27th, 2010, 8:42am
 
thescruff wrote on May 26th, 2010, 1:26am:
A cross flow top one side bottom the other is best, is they don't specify an order.



Thank you!  Grin
Back to top
 
Thank User For This Post  
IP Logged
 
pryantcc
Re: Question on hooking up my new oil boiler
Reply #8 - Jul 4th, 2011, 1:46pm
 
Apologies for resurrecting a very old thread, but I thought you might find it interesting to know how I got on.

The boiler install went very well. I managed to borrow a fuel pressure guage and exhaust gas analyser from a friend, then using the manufacturer's instructions, I set everything up.

The boiler ran all last winter and I estimate that it halved my oil consumption while also improving the warmth in the house.

The old boiler was about 30 to 40m from the hot water cylinder, I sited the new one only 6m away. The new boiler has about 20% higher output rating, but is still proving far more efficient.

Thanks to everyone who responded to my questions!
Back to top
 
Thank User For This Post  
IP Logged
 
woodsmith
Global Moderator
Trade Member
Author
*****
Offline


Posts: 4405


Total Thanks: 137
For This Post: 0


Gender: male

Trade: Joiner

Re: Question on hooking up my new oil boiler
Reply #9 - Jul 5th, 2011, 8:08am
 
Thanks for coming back and letting us know how you got on  Smiley
Back to top
 
Thank User For This Post View members image gallery  
IP Logged
 