Ideal Isar HE30?? not working (Read 12739 times)
wozzy
Trade Member
Offline
Ask The Trades
Posts: 584
Total Thanks: 4
For This Post: 0
Gender:
Trade: Electrician
Ideal Isar HE30?? not working
Jul 8
th
, 2010, 6:45pm
Brilliant
Came home just now to a not working combi, not lights will light up or anything, ive checked the fuse in the plug and the glass fuse on the PCB all ok. Ive checked the mains plug is in and getting voltage on the other side of it.
Is there anything else to check, before i ask a heating engineer to have a look?
Back to top
All advice is at least two years out of date.
IP Logged
wozzy
Trade Member
Offline
Ask The Trades
Posts: 584
Total Thanks: 4
For This Post: 0
Gender:
Trade: Electrician
Re: Ideal Isar HE30?? not working
Reply #1 -
Jul 8
th
, 2010, 7:30pm
o dear the internet doesnt make for good reading on this subject.
Back to top
All advice is at least two years out of date.
IP Logged
thescruff
Global Moderator
Trade Member
Author
Offline
Who said plumbing was
easy.
Posts: 6037
Total Thanks: 147
For This Post: 0
Gender:
Trade: Plumber
Re: Ideal Isar HE30?? not working
Reply #2 -
Jul 8
th
, 2010, 7:35pm
When you say no power, what if anything do you get on L1, L2, L3, and is the plug right in.
Whats the pressure reading.
The boiler on switch is on.
Have you pressed the reset button, and held it in for a few seconds.
Back to top
IP Logged
wozzy
Trade Member
Offline
Ask The Trades
Posts: 584
Total Thanks: 4
For This Post: 0
Gender:
Trade: Electrician
Re: Ideal Isar HE30?? not working
Reply #3 -
Jul 8
th
, 2010, 7:49pm
cheers for the help scruff much appreciated.
When i get the progrmmer to call i get 230v between all three lives to earth and 230 between all lives and neutral, this is on the boiler side of the plug so voltage is in there and getting to the control panel.
0.5 bar on the gauge.
yes tried holding the reset button in for a bit. Ive left the boiler turned off and turned it back on and tried agin. Getting worried now
Back to top
All advice is at least two years out of date.
IP Logged
thescruff
Global Moderator
Trade Member
Author
Offline
Who said plumbing was
easy.
Posts: 6037
Total Thanks: 147
For This Post: 0
Gender:
Trade: Plumber
Re: Ideal Isar HE30?? not working
Reply #4 -
Jul 8
th
, 2010, 7:54pm
Are you saying you have 240vac on the above 3 terminals.
Increase the pressure to 1.2bar.
Back to top
IP Logged
wozzy
Trade Member
Offline
Ask The Trades
Posts: 584
Total Thanks: 4
For This Post: 0
Gender:
Trade: Electrician
Re: Ideal Isar HE30?? not working
Reply #5 -
Jul 8
th
, 2010, 8:14pm
yes L1 L2 L3 all have voltage on them.
I have limited knowledge of plumbing, how do i increase pressure? the only time i have ever done this before is with a filling loop and i dont think i have one of these.
Back to top
All advice is at least two years out of date.
IP Logged
thescruff
Global Moderator
Trade Member
Author
Offline
Who said plumbing was
easy.
Posts: 6037
Total Thanks: 147
For This Post: 0
Gender:
Trade: Plumber
Re: Ideal Isar HE30?? not working
Reply #6 -
Jul 8
th
, 2010, 8:32pm
You should have a filler loop somewhere.
You don't have a header tank in the loft, I hope.
Back to top
IP Logged
wozzy
Trade Member
Offline
Ask The Trades
Posts: 584
Total Thanks: 4
For This Post: 0
Gender:
Trade: Electrician
Re: Ideal Isar HE30?? not working
Reply #7 -
Jul 9
th
, 2010, 7:53pm
no tank in loft just couldnt see filling loop.
Cheers for all the help scruff.
I managed to get hold of a couple heating engineer mates who said PCB straight away. So i went for the BG fixed price repair, after being advised they may have the parts in stock and probably replace PCB and control panel. Unfortunately they didnt have parts in stock but are replacing both monday so i think i got my moneys worth out of them!
Back to top
All advice is at least two years out of date.
IP Logged
thescruff
Global Moderator
Trade Member
Author
Offline
Who said plumbing was
easy.
Posts: 6037
Total Thanks: 147
For This Post: 0
Gender:
Trade: Plumber
Re: Ideal Isar HE30?? not working
Reply #8 -
Jul 10
th
, 2010, 1:05am
Sorry not convinced although the PCB would be a good place to start, you should at least have signs of life on the front panel.
Back to top
IP Logged
wozzy
Trade Member
Offline
Ask The Trades
Posts: 584
Total Thanks: 4
For This Post: 0
Gender:
Trade: Electrician
Re: Ideal Isar HE30?? not working
Reply #9 -
Jul 12
th
, 2010, 8:44pm
fixed, although didnt get a new control panel but not moaning as the old one is still functioning and the repair wasnt bad value for money.
Ive always believed a PCB would bring up a fault code, but after alot of research on these poor boilers it appears its the transformer that gives up hence no power anywhere or anything. Shame you cant just replace the transformer and not the whole PCB!
Back to top
All advice is at least two years out of date.
IP Logged
Pages: 1
(Moderator: thescruff) - (Moderator Group: Board Moderator)
<
Previous Topic
|
Next Topic
>
Ask The Trades
›
DIY Forum
›
Plumbing Questions
› Ideal Isar HE30?? not working
Forum Jump »
Home
» 10 most recent Posts
» 10 most recent Topics
DIY Forum
- Electrical Questions
- Plumbing Questions ««
- Carpentry Questions
- Building Questions
- Painting, Decorating & Tiling Questions
- Alarms, Phones, Aerials, CCTV & Datacomms
Public Forum
- Just Talk
- Humour
- The Forum
- Trade Applications
Ask The Trades
» Powered by
YaBB 2.3
!
YaBB
© 2000-2008. All Rights Reserved.